Set-up 4
0020077989_04 auroTHERM exclusive Installation and maintenance instructions
19
L
1
L
2
.............
.............
L
1
L
2
L
1
L
1
½
L
1
½
L
2
½
L
2
½
L
2
5.
Use the tables to determine the required weights.
Vertical collector position
Installation angle 30°
Weights/rack [kg]
L
1
L
2
To secure against sliding and
lifting
To secure only against lifting
(if secured/anchored against
sliding)
Note
If the collectors are also anchored using steel ropes from the installation set
for the storm protection, the reduced weights can only be used to protect
against lifting.
When there are at least two collectors in a row, the ballast loads can be re-
duced by half for the outer rack.
Basic wind speed [km/h]
Store
Building height
Building height
up to 10
m
10-18 m
18-25 m
up to 10
m
10-18 m
18-25 m
up to 72
Inland
L
₁
L
₂
301
167
378
213
429
244
44
167
40
213
70
244
up to 72
Coast and islands
L
₁
L
₂
413
234
487
279
534
307
67
234
81
279
90
307
up to 81
Inland
L
₁
L
₂
357
201
469
268
544
313
56
201
78
268
92
313
up to 81
Coast and islands
L
₁
L
₂
527
303
621
359
680
395
89
303
108
359
119
395
up to 90
Inland
L
₁
L
₂
469
268
581
335
656
380
78
268
100
335
115
380
up to 90
Coast and islands
L
₁
L
₂
619
358
731
425
806
470
107
358
129
425
144
470
up to 99
Inland
L
₁
L
₂
581
335
694
403
806
470
100
335
122
403
144
470
up to 99
Coast and islands
L
₁
L
₂
768
448
881
515
955
560
137
448
159
515
174
560
up to 108
Inland
L
₁
L
₂
694
403
843
492
955
560
122
403
152
492
174
560
up to 108
Coast and islands
L
₁
L
₂
918
537
1030
605
1143
672
166
537
188
605
211
672