21
Flue installation instructions ecoTEC 834449_13
Fig. 2.31 Bird protection grille
Fig. 2.32 Installation of basic kit with two additional 87° bends
showing position of support clips
Fig. 2.33 Installation of basic kit with two additional 45° bends
showing position of support clips
• Fit the pipes and bends, working from the variable ter-
minal to the selected location for the flue exit using
support clips supplied fig. 2.30, 2.31, 2.32 or 2.33.
a
Caution!
Pipe extensions must be fixed to the wall using
support clips. Use one clamp for each extension
directly beside the sleeve. Fit another clamp to
the extension after each 87° bend (fig. 2.32).
Caution!
The extension pipe expands when heated. Leave
1 cm expansion space in eachsleeve.
h
Note
The maximum flue lengths where the variable
termination kit is installed are shown in tables
2.3 and 2.4.
Note
The parts are simply pushed together (not bolt-
ed).
a
Caution!
Fasten the 87° bend with bird protection grille
using a separate support clip (fig. 2.31).