11 Decommissioning
22
Installation
instructions
electronicVED
plus
0020288449_01
At the same time, the water filter has a
sealing function.
▶
Replace the water filter in the cold water
flow. For the sealing function, ensure
that it is positioned correctly in the pipe.
▶
Check for deposition in the domestic hot
water pipe between the heating block
and the domestic hot water connection.
▶
When re-assembling the product, insert
a new flat seal into the domestic hot
water connection.
▶
Check whether it is necessary to de-
scale the product. De-scale the product
as required.
▶
If the product needs to be completely
descaled, attach a descaling pump
between the domestic hot and cold wa-
ter connection.
▶
After descaling the product, flush it thor-
oughly with water.
▶
After descaling, draw off water using
the product to remove any air pockets.
(
→
Page 18)
11 Decommissioning
11.1 Temporarily decommissioning
the product
1. Disconnect the product from the power
supply.
2. Close the cold water stop valve.
11.2 Permanently decommissioning
the product
1. Disconnect the product from the power
supply.
2. Close the cold water stop valve.
3. Loosen the cold water and hot water
connections.
4. Capture the residual water (up to 0.4
litres) that is left inside the product us-
ing a suitable vessel.
5. Remove the product.
Summary of Contents for 0010023770
Page 55: ...1 53 1 1 1 3 0020288449_01 electronicVED plus 1 2 1 3 55 C...
Page 58: ...8 56 electronicVED plus 0020288449_01 8...
Page 61: ...1 59 1 1 1 IP 0020288449_01 electronicVED plus 1 2 1 2 1 1 2 2 1 2 3 3 mm...
Page 70: ...10 68 electronicVED plus 0020288449_01 10 65 11 11 1 1 2 11 2 1 2 3 4 0 4 5...
Page 75: ...0020288449_01 electronicVED plus Country specifics 73...