5 Installation
16
Installation
instructions
electronicVED
plus
0020288449_01
1
2
3
4
5. Fit the product
(2)
to the retaining
screw
(1)
on the mounting plate.
6. Use the adjustment spindle
(4)
to ad-
just the product.
7. Use the fixing screw
(3)
to secure the
product.
5 Installation
1. If you are using plastic pipes, only use
those that are approved for normal
operating mode at 65 °C.
2. If you are using plastic pipes, only use
those that maintain a maximum tem-
perature of 95 °C and a maximum
pressure of 1 MPa (10 bar) for at least
one hour (check the manufacturer de-
tails).
3. Flush the cold water pipes thoroughly
before installation.
5.1 Setting up the domestic hot and
cold water connection
1. Note the water connections for the
installation:
–
An expansion relief valve on the cold
water pipe is not required.
–
All hot and cold water pipes can be
made of steel, copper or plastic.
–
The product must be permanently
connected to permanently installed
water pipes. It must not be temporar-
ily connected to hose lines.
–
You must not connect any water
supply pipes from other water-heat-
ing systems to the product's cold wa-
ter connection.
–
You must not directly connect water
taps or similar to the product's do-
mestic hot water connection.
1
2. To simplify installing the water con-
nection, the bottom section of product
frame can be folded up
(1)
.
–
Do not remove the folding frame.
Summary of Contents for 0010023770
Page 55: ...1 53 1 1 1 3 0020288449_01 electronicVED plus 1 2 1 3 55 C...
Page 58: ...8 56 electronicVED plus 0020288449_01 8...
Page 61: ...1 59 1 1 1 IP 0020288449_01 electronicVED plus 1 2 1 2 1 1 2 2 1 2 3 3 mm...
Page 70: ...10 68 electronicVED plus 0020288449_01 10 65 11 11 1 1 2 11 2 1 2 3 4 0 4 5...
Page 75: ...0020288449_01 electronicVED plus Country specifics 73...