SMGM FIELDBUS TYPES
108
PROFINET module: Event log
Submodule
Designation
Type
Content
1
Event log index
1 Word input
Index of the event
2
Event log time stamp
4 Word input
Time stamp of the event
3
Event log device-id
4 Bytes input
The last four digits of the SMGM module
MAC address
•
Byte0: MAC 3rd octet
•
Byte1: MAC 4th octet
•
Byte2: MAC 5th octet
•
Byte3: MAC 6th octet
4
Event log code
1 Word input
Code of the event
5
Event log data
16 Bytes input
Data of the event