Technical Data

Voltage drop: 10% max.

The VAHLE POWERCOM

®

 485 devices support only one of the data transmissi-

on rates defined in the DIN 19 245 specification: 9.6 kbit/s or 19.2 kbit/s depend-
ing on the device type.

The VAHLE POWERCOM

®

 485 devices regenerate the signal form and ampli-

tude of the received data.

Note:
Due to the complexity and versatility of switching power supplies a custo-
mer's  check  in  connection  with  Vahle  -  electronic  components  is  recom-
mended.

1.1.4

Wiring the conductor rails

Some special features must be observed when wiring the conductor rails.

Type

Length of transmission

Devices/Segment Description

Order-Nr.

VAHLE POW-
ERCOM

®

 485 

230V

up to 5000m

64

Additional interface: 
Allen-Bradley DH 485, 
MODBUS
Power -10%
Weight: 1100g

910 108

VAHLE POW-
ERCOM

®

 485 

115V

up to 5000m

64

910 109

Parameter

Dimension

Gewicht

[g]

1100

Dimension (HxWxD)

[mm]

117x85x110

Operation temperature

[°C]

-20...+50

Storage temperature

[°C]

-20...+50

Operation voltage

[VDC]

230 (115 option)

Power demand

[W]

max. 20

Current consumption

[A]

0,08 (230VDC) / 0,18 (115VDC)

Protection class

IP20

Summary of Contents for POWERCOM 485

Page 1: ...DESCRIPTION AND OPERATING INSTUCTIONS 6A EN 2014 POWERCOM 485...

Page 2: ...We point out that the contents of these operating instructions are not part of a for mer or existing agreement promise or legal relationship or intended to modify any such relationship All obligations...

Page 3: ...ut problems in an EMC suitable environment see also EMC suitable installation and configuration of VAHLE electronic components The cable and devices in the switch cabinet must comply with the relevant...

Page 4: ...485 devices regenerate the signal form and ampli tude of the received data Note Due to the complexity and versatility of switching power supplies a custo mer s check in connection with Vahle electron...

Page 5: ...Comply with the following directives when designing your device configuration The VAHLE POWERCOM 485 device is designed for heat removal by natu ral convection Therefore leave a clear space of at leas...

Page 6: ...tance grounded top hat rail or mounting plate 1 1 6 Installing a VAHLE POWERCOM 485 device Warning If the supply voltage for the VAHLE POWERCOM 485 devices and all con nected devices is not switched o...

Page 7: ...n press the underside onto the bus rail until it latches audibly Make sure that the device is securely attachedon the rail To remove it press the device downwards Note In environments subject to stron...

Page 8: ...es with appropriate conductor size for the current amperage required The VAHLE POWERCOM 485 devices can be wired with lines having a con ductor cross section area between AWG 20 14 Do not over tighten...

Page 9: ...ed PROFI BUS Ethernet Bus signals unshielded AS Interface Data signals shielded PG counting inputs etc Analog signals shielded Direct vol tage 60 V unshielded process signals 25 V shielded alternating...

Page 10: ...h optical waveguide cables The PROFIBUS connection is designed as 9 pole subminiature D plug connec tor The pin assignment corresponds to the PROFIBUS standard configuration A short circuit proof 5 Vo...

Page 11: ...ROFIBUS parameter TTD increase instead both two times min RSDR and max TSDR by 2 x TTD in each case the reaction time of the respon der is extended by the transmission delay time for the outgoing and...

Page 12: ...nnnnn 06PC EN 009_23 09 2014 fm Stand 23 09 2014 3 Please determine the transmission delay times from the respective product do cumentation for other active PROFIBUS network components 4 Transmission...

Page 13: ...he Profibus transmission Following steps in the HW Config Opening of the tab General and select properties Network settings tab in the DP Master system Set of User defined in the profile Select the bu...

Page 14: ...n additional double fil ter Use of a vehicle side double filter to avoid faults ATTENTION Power supply may only be used for control units Motors frequency con verters or similar may not be connected 6...

Page 15: ...ice is suspected defective 1 1 15 Service customer service repairs replacement parts In all cases of disturbance arising in connection with the data transmission in par ticular when the described test...

Page 16: ...Paul Vahle GmbH Co KG Westicker Str 52 59174 Kamen Germany Tel 49 2307 704 0 Fax 49 2307 704 444 info vahle de www vahle com...

Reviews: