Warning
Failure to observe the warning instructions can lead to severe injuries and/
or material damage. Only properly qualified personnel should work on or in
the vicinity of this device. These personnel must be thoroughly familiar with
all warnings and maintenance tasks according to these operating instruc-
tions. Correct and safe operation of this device is subject to proper trans-
portation,  storage  and  installation  as  well  as  careful  operation  and
maintenance.

1.1.2

General

Figure 2
Overview of 
connection from 
VAHLE 
POWERCOM

®

 

components

The connection to the data transmission path must be established via an in line
fuse.
To protect the VAHLE POWERCOM transmission against external disturbances,
such as control signals of the electric power supply companies, a dual filter must
always be installed at the input.
VAHLE POWERCOM units can only operate safely and without problems in an
EMC suitable environment (see also "EMC-suitable installation and configuration
of VAHLE electronic components”).
The cable and devices in the switch cabinet must comply with the relevant regu-
lations and must not be installed together with the electric power cables.
The instructions of the equipment suppliers must be complied with in plants with
frequency  converters,  in  particular  with  regard  to  interference  suppression
measures, separation distances and cable shielding.
Data transmission has been tested and approved only with VAHLE conductor rail.
The feed via vehicles must always be made with dual current collectors. Special
measures are required for heated conductor rail.
Any consumer devices connected via the data conductor rails must be equipped
with a dual filter.

Einspeisung CONNECTION

400V/50Hz (480V/60Hz)

RC

DOPPELFILTER
DUAL FILTER
230 VAC / 50 Hz / 6A

Einspeisung CONNECTION

230V/50Hz max. 6A (115V/60Hz)

XL XL

XN XN

SPS/PLC

6-polige Schleifleitung
CONDUCTOR RAILS

SPS/PLC

Steuerung
CONTROL

RC

VAHLE
POWERCOM®485

VAHLE
POWERCOM®485

SPS/PLC

Steuerung
CONTROL

VAHLE
POWERCOM®485

-X10

L1

L2

L3

PE

-DF

/1.3

L

N

PE

-X1

1

2

3

-X2:4

5

6

7

L

L

N

N

PE XN

XL

-PC

/1.4

-L

-N

-PE -XN -XL

-L

-N

-PE -XN -XL

Summary of Contents for POWERCOM 485

Page 1: ...DESCRIPTION AND OPERATING INSTUCTIONS 6A EN 2014 POWERCOM 485...

Page 2: ...We point out that the contents of these operating instructions are not part of a for mer or existing agreement promise or legal relationship or intended to modify any such relationship All obligations...

Page 3: ...ut problems in an EMC suitable environment see also EMC suitable installation and configuration of VAHLE electronic components The cable and devices in the switch cabinet must comply with the relevant...

Page 4: ...485 devices regenerate the signal form and ampli tude of the received data Note Due to the complexity and versatility of switching power supplies a custo mer s check in connection with Vahle electron...

Page 5: ...Comply with the following directives when designing your device configuration The VAHLE POWERCOM 485 device is designed for heat removal by natu ral convection Therefore leave a clear space of at leas...

Page 6: ...tance grounded top hat rail or mounting plate 1 1 6 Installing a VAHLE POWERCOM 485 device Warning If the supply voltage for the VAHLE POWERCOM 485 devices and all con nected devices is not switched o...

Page 7: ...n press the underside onto the bus rail until it latches audibly Make sure that the device is securely attachedon the rail To remove it press the device downwards Note In environments subject to stron...

Page 8: ...es with appropriate conductor size for the current amperage required The VAHLE POWERCOM 485 devices can be wired with lines having a con ductor cross section area between AWG 20 14 Do not over tighten...

Page 9: ...ed PROFI BUS Ethernet Bus signals unshielded AS Interface Data signals shielded PG counting inputs etc Analog signals shielded Direct vol tage 60 V unshielded process signals 25 V shielded alternating...

Page 10: ...h optical waveguide cables The PROFIBUS connection is designed as 9 pole subminiature D plug connec tor The pin assignment corresponds to the PROFIBUS standard configuration A short circuit proof 5 Vo...

Page 11: ...ROFIBUS parameter TTD increase instead both two times min RSDR and max TSDR by 2 x TTD in each case the reaction time of the respon der is extended by the transmission delay time for the outgoing and...

Page 12: ...nnnnn 06PC EN 009_23 09 2014 fm Stand 23 09 2014 3 Please determine the transmission delay times from the respective product do cumentation for other active PROFIBUS network components 4 Transmission...

Page 13: ...he Profibus transmission Following steps in the HW Config Opening of the tab General and select properties Network settings tab in the DP Master system Set of User defined in the profile Select the bu...

Page 14: ...n additional double fil ter Use of a vehicle side double filter to avoid faults ATTENTION Power supply may only be used for control units Motors frequency con verters or similar may not be connected 6...

Page 15: ...ice is suspected defective 1 1 15 Service customer service repairs replacement parts In all cases of disturbance arising in connection with the data transmission in par ticular when the described test...

Page 16: ...Paul Vahle GmbH Co KG Westicker Str 52 59174 Kamen Germany Tel 49 2307 704 0 Fax 49 2307 704 444 info vahle de www vahle com...

Reviews: