Error description

Item

Error description

Possible cause

Measure

1

Vehicle comes to a halt or will 
not move on the open road

Contamination of the conduc-
tor rails

Clean the conductor rails ac-
cording to the corresponding 
information from the related 
Vahle documentation for con-
ductor rails

2

Vahle RC closures are not cor-
rectly connected

Check closures according to 
the Powercom documentation

3

Closures at the profibus cables 
are not correctly configured

Check the stationary and mo-
bile profibus connectors

4

Faults on the conductor rails 
are too figh

Check installation of Vahle 
double filter and configuration 
of sensitivity (the latter only 
with Vahle Powercom 485 HD)

5

Vehicle-side third party use of 
the Powercom power supply 
without an additional double fil-
ter

Use of a vehicle-side double 
filter to avoid faults;
ATTENTION: Power supply 
may only be used for control 
units! Motors, frequency con-
verters or similar may not be 
connected!

6

No double current collector 
used

Mount double current collector 
according to the relevant 
Vahle documentation for con-
ductor rails.
ATTENTTION: Only current 
collectors approved by Vahle 
are permitted.

7

Vehicle sporadically reports 
faults at a segment transition

Contamination of the conduc-
tor rails

Clean the conductor rails ac-
cording to the corresponding 
information from the related 
Vahle documentation for con-
ductor rails

8

Conductor is no longer correct-
ly aligned (vertical offset of the 
conductor rails for data trans-
fer)

Orientation of the conductor 
rails

9

Segment filtes are not correct-
ly connected (only affects 
Vahle Powercom 485 HD)

Check the segment filters ac-
cording to the Powercom doc-
umentation.

10

Accumulation of undefinable 
faults

Current collectors have worn

Exchange of the current col-
lectors according to the rele-
vant Vahle documentation for 
conductor rails

Summary of Contents for POWERCOM 485

Page 1: ...DESCRIPTION AND OPERATING INSTUCTIONS 6A EN 2014 POWERCOM 485...

Page 2: ...We point out that the contents of these operating instructions are not part of a for mer or existing agreement promise or legal relationship or intended to modify any such relationship All obligations...

Page 3: ...ut problems in an EMC suitable environment see also EMC suitable installation and configuration of VAHLE electronic components The cable and devices in the switch cabinet must comply with the relevant...

Page 4: ...485 devices regenerate the signal form and ampli tude of the received data Note Due to the complexity and versatility of switching power supplies a custo mer s check in connection with Vahle electron...

Page 5: ...Comply with the following directives when designing your device configuration The VAHLE POWERCOM 485 device is designed for heat removal by natu ral convection Therefore leave a clear space of at leas...

Page 6: ...tance grounded top hat rail or mounting plate 1 1 6 Installing a VAHLE POWERCOM 485 device Warning If the supply voltage for the VAHLE POWERCOM 485 devices and all con nected devices is not switched o...

Page 7: ...n press the underside onto the bus rail until it latches audibly Make sure that the device is securely attachedon the rail To remove it press the device downwards Note In environments subject to stron...

Page 8: ...es with appropriate conductor size for the current amperage required The VAHLE POWERCOM 485 devices can be wired with lines having a con ductor cross section area between AWG 20 14 Do not over tighten...

Page 9: ...ed PROFI BUS Ethernet Bus signals unshielded AS Interface Data signals shielded PG counting inputs etc Analog signals shielded Direct vol tage 60 V unshielded process signals 25 V shielded alternating...

Page 10: ...h optical waveguide cables The PROFIBUS connection is designed as 9 pole subminiature D plug connec tor The pin assignment corresponds to the PROFIBUS standard configuration A short circuit proof 5 Vo...

Page 11: ...ROFIBUS parameter TTD increase instead both two times min RSDR and max TSDR by 2 x TTD in each case the reaction time of the respon der is extended by the transmission delay time for the outgoing and...

Page 12: ...nnnnn 06PC EN 009_23 09 2014 fm Stand 23 09 2014 3 Please determine the transmission delay times from the respective product do cumentation for other active PROFIBUS network components 4 Transmission...

Page 13: ...he Profibus transmission Following steps in the HW Config Opening of the tab General and select properties Network settings tab in the DP Master system Set of User defined in the profile Select the bu...

Page 14: ...n additional double fil ter Use of a vehicle side double filter to avoid faults ATTENTION Power supply may only be used for control units Motors frequency con verters or similar may not be connected 6...

Page 15: ...ice is suspected defective 1 1 15 Service customer service repairs replacement parts In all cases of disturbance arising in connection with the data transmission in par ticular when the described test...

Page 16: ...Paul Vahle GmbH Co KG Westicker Str 52 59174 Kamen Germany Tel 49 2307 704 0 Fax 49 2307 704 444 info vahle de www vahle com...