7
5.
The
“Lights“
and
“Atr/Atr 2“
menus allow the user to set operating timers for
these outputs with a 15 min. step (0-120 for Atr, 0-240/ON for Lights):
a)
Select “
>Lights
“ and press “
ENT/ESC
“ button,
b)
Press “
SET/SEND
“ button to start to set timer,
c)
Press “
V
“ to
decrease operation time (1 click = -15 min),
d)
Press “
ꓥ
“ to increase operation time
(1 click = +15 min),
e)
Press “
SET/SEND
“ to
confirm and send changes to DIN
module,
f)
A
“
Sending
…
“ message will be displayed
.
Note:
The quick-access F1 button (Lights by default) also allows permanent ON ((000
–
ON
–
015
–
030 … 240 min).
6.
The
“Heating/Cooling” menu allows the user to set the heating / cooling and water
temp.:
g)
In main menu, select “
>Temperature
“ and press “
ENT/ESC
“
button,
h)
Press “
SET/SEND
“ button to start to set temperature,
i)
Press “
V
“ to decrease temperature (1 click =
-
1°C),
j)
Press “
ꓥ
“ to increase temperature (1 click = +1°C),
k)
Press “
<>
“ to
select operation heating or cooling mode,
l)
Press “
SET/SEND
“ to confirm and send changes to DIN module,
m)
A
“
Sending
…
“ message will be displayed
.
Note:
Preset output delay
–
in this case 8 mins remain to heating power ON (preset delay 10) and
allowed operating temperature
range
are preset in the system. These technology-protecting parameters can be modified only by authorized person.
The heating priority function can be configured with DIP Switch 4
. With heating priority deactivated, heating/cooling may
be active only when the filtration is running. Also, the operating protections will not be active. Heating is OFF by default
(temp setting), while heating priority default value is ON (page 5).
7.
The “Time
/
Date”
menu allows the user to set system time and date
–
important
for proper filtration and dosing/salinator functioning:
n)
Select “
>Time/Date
“ and press “
ENT/ESC
“ button,
o)
Press “
SET/SEND
“ button to set time and date,
p)
Press
“
V
“
to adjust minutes (1 click = +5 min),
q)
Press
“
ꓥ
“
to adjust hours (1 click = +1 hour),
r)
Press “
<>
“ to move to next parameter (d/m/y),
s)
Press “
V
“ and “
ꓥ
“ to adjust the selected parameter,
t)
Press “
SET/SEND
“ to
confirm and send changes to DIN module,
u)
As a safety precaution, a “
Verification code
” must be entered.
v)
A
“
Sending
…
“ message will be displayed; in case wrong code is
entered the
“
Wrong code
” message will appear.
Note:
Default verification code is 1234
. Only an authorized person may change the verification code.
When a wrong code is entered, changes will not be sent to the DIN module
and the unit will return to original settings
.
8.
The
“
Language
“
menu allows the user to select the language:
a)
Select
“
>Language
“
and confirm with
“
ENT/ESC
“,
b)
Press
“
V
“
to select language (CZ/EN/HR/FR/DE/ES),
c)
Press
“
ꓥ
“
to select language,
d)
Press “
SET/SEND
“ to
confirm and send changes to DIN module,
e)
A
“
Sending
…
“ message will be displayed
Lights
015min
Lights
045min
Lights
075min
Attraction
030min
Lights
120min
Attraction
060min
Attraction
090min
Attraction
000min
Heating
29°C
Filtration
[ZAP]
Dosing
[ZAP]
Temperature25°C
[-08]
Lights
014
Atr
015
Cooling
27°C
Time
14:10
Day
27
Month
07
Year
18
Verification code
0 0 0 0
Wrong code
Czech
Summary of Contents for VArio DIN module
Page 1: ...1 20 02_ver 1 11_VA SYST M ZEN BAZ NOV TECHNOLOGIE RC modul d lkov ovl d n CZ EN DE HR...
Page 17: ...19 08_ver 1 11_VA POOL TECHNOLOGY CONTROL SYSTEM RC Module remote control...
Page 33: ...1 19 08_ver 1 11 SCHWIMMBADTECHNIK STEUERANLAGE RC Modul Fernbedienung...
Page 49: ...1 19 08_ver 1 11_VA SUSTAV UPRAVLJANJA BAZENSKOM TEHNOLOGIJOM RC modul daljinsko upravljanje...