6
7.4.
Controlling the DIN module with RC module
5 outputs can be activated in the configuration menu:
Filter pump
with up to 4 programmable
daily cycles and 2 user regimes,
Dosing
(Salinator)
based on filtration time,
Heating / Cooling
function with regard to preset water temperature,
Lights
and
Attraction
(e.g. counterflow) with timer.
1.
Press the “ “
button to wake the RC from the sleeping mode.
2.
Press the
“
V
“ button
to enter the configuration menu:
a)
Press
“
V
“
to move down in the menu,
b)
Press
“
ꓥ
“
to move up in the menu,
c)
The “
>
” arrow indicates the selected
parameter,
d)
Press the “
ENT/ESC
“ key to enter to selected parameter menu.
Flashing rectangle on the display indicates ongoing
information transfer between the DIN and RC modules
–
wait
for the communication to finish in order to change the
parameter setting.
3.
The “
Filtration
“ menu
allows the user to set up to 4 running cycles within 24 hours:
a)
In main menu, select “
>Filtration
“ and press “
ENT/ESC
“
button,
b)
Press
“
SET/SEND
“ button to activate the timer set mode,
c)
Press
“
V
“
to adjust minutes (1 click = +5 min),
d)
Press
“
ꓥ
“
to adjust hours (1 click = +1 hour),
d)
Press
“
<>
“
to move to the next timer,
e)
Press
“
SET/SEND
“
to confirm and send changes to DIN module,
f)
A
“
Sending
…
“ message will be displayed.
Note:
The first cycle starting time (in this case 07:00) also determines the starting time for salinator/dosing unit in automatic
operation mode. When setting the intervals, the first time must be lower than the second; also, you cannot pass midnight
within the same interval (e.g. 09:30-06:00). System will not accept such invalid intervals..
4.
The
“
Filtration-
mode“ menu allows the user to select th
e operating mode of filtration:
a)
Select
“
>Filtration-mode
“ and confirm with „E
NT/ESC
“,
b)
Press
“
V
“
to scroll through modes (AUTO/ZAP/XXCL/VYP),
c)
Press
“
ꓥ
“
to select mode,
g)
Press
“
SET/SEND
“
to confirm and send changes to DIN module,
h)
A
“
Sending
…
“ message will be displayed.
i)
Atraction2
>Filtration
Filtration-mode
Lights
Heating/Cooling
Atr
>Time/Date
Language
Lights-setting
Dosing
07:00
10:00
12:00
15:00
16:00
19:00
21:00
23:00
Filtration
[AUTO]
Summary of Contents for VArio DIN module
Page 1: ...1 20 02_ver 1 11_VA SYST M ZEN BAZ NOV TECHNOLOGIE RC modul d lkov ovl d n CZ EN DE HR...
Page 17: ...19 08_ver 1 11_VA POOL TECHNOLOGY CONTROL SYSTEM RC Module remote control...
Page 33: ...1 19 08_ver 1 11 SCHWIMMBADTECHNIK STEUERANLAGE RC Modul Fernbedienung...
Page 49: ...1 19 08_ver 1 11_VA SUSTAV UPRAVLJANJA BAZENSKOM TEHNOLOGIJOM RC modul daljinsko upravljanje...