installation
4
temperature resetting
assembly and installation
5
20
50
38
Rinse pipeworks carefully for a long while before fitting the valve: do not allow dirt,
metal particles or shavings to block the filters fitted on inlets.
Warning!
Please check for any hidden cables and pipes before drilling holes in the
wall.
The valve must be set into the wall between (27mm minimum – 55mm maximum)
If you are fitting the valve to a partition wall or a wall of particularly soft substrate you
will need specialist fixings.
Select the position for the shower valve and offer the shower valve to the wall, mark
the 2 fixing points with a suitable pencil. Remove the shower valve from the wall, drill
the holes to a suitable depth for the wall plugs and secure with suitable screws.
During and after installation protect the outer parts by leaving the plastic sleeve on the
valve to avoid damage to plated surfaces.
Connect hot supply to left inlet of the valve and cold supply to right inlet.
Make all connections to the valve. The valve is supplied with an additional tapping at
its base – for jet or bathfiller spout.
Slide the cover plate over the valve. Push on the stop ring with the notch at the 12
o’clock position, followed by the valve ring with the button at 6 o’ clock and secure
using the retaining screw do not over tighten. Push on the control handle body taking
care that the handle is fully located over the brass end and engaging with the nylon
shaft (if necessary gently tap the handle onto the shaft using a rubber mallet or similar
in order to avoid damaging the handle finish and taking care to support the valve
body). Tighten the allen bolt, screw on the handle. Finally screw on the diverter button.
The valve has been factory set under balance pressures and hot water supply at 65° C.
When your specific operating conditions are significantly different from the above, the
temperature of the water may vary from the setting.
When the difference is too great, you can adjust the calibration of the valve to suit
individual requirements of the installation.
1. Select 38° C or the arrow on the handle and check the temperature of the water
being delivered to the showerhead with a thermometer:
2. If the temperature is unacceptable proceed to reset the calibration as follows:
Remove the handle, valve ring, stop ring and push the control arm to the up position.
Insert an hexagonal key into the temperature resetting screw and turn anti-clockwise
to increase the temperature and clockwise to decrease the temperature. Turning the
resetting screw 180° in either direction will increase or decrease the temperature by 2°
3. Replace the valve rings and handle, do not overtighten the screw.
42mm
Valve centre line
Valve fixing
holes
28mm
Pipe connection centre line
Hot inlet
Cold inlet
Outlet
Valve
fixing
holes
Valve
Cover plate
Valve ring
(button at
6 o’clock)
Diverter
button
Flow/ Temperature
control body
Temperature
stop button
handle
Stop ring
(notch at
12 o’clock)
Screw
Control arm
Temperature
resetting screw
ZOO 147T Pag.indd 4
11/2/10 11:29:22