Installation

1)

2)

Important Information

*

*

Brazed connections should not be made directly onto

the mixer, as excessive heat will coause permanant damage.

Attach inwall body mounting box (11) to timber noggins

as shown (Fig.3) using the 6 off supplied screws (1). Use

the integrated level indicator (2) to ensure that the box

is mounted 

horizontally.

Remove cover (3) by unscrewing the 4 off plastic

socket screws (4) using the supplied spanner.

3) Remove sealing grommet (5). Insert DN15 

copper mains supply pipe through grommet, 

and then insert pipe into box. Assemble compression

fitting and make connection with the G1/2 integrated 

isolation valve (6). After connection has been made,

slide sealing grommet back onto mounting box. Ensure

that the isolation valve (7)  is in the CLOSED POSITION

as shown (Fig.1). Open mains supply & check for leaks.

Connect power supply (8) to a 240VAC, 10A GPO.

Ensure that supply of power has been isolated.

The power outlet should be located no more

than 2.2m from the inwall body box when using the 

supplied extension cable (9). 

Connection points (10) are provided for terminating standard

20mm electrical conduit to the mounting box.

Run cable through connection points and into the mounting box .

Once inwall body installation has been completed,

replace & secure mounting box cover (3) using

screws (4). Complete lining & tiling process. After

tiling is complete, trim excess mounting box tiling

flange so that it flush with the  finshed surface (Fig.2).

Re-attach mouting box cover (3) using the screws (4).

4)

5)

All pipework must be throroughly flushed prior to installation.

Refer to side 2 of this instruction for trim kit installation.

*

PLUMBERS INSTALLATION INSTRUCTIONS - INWALL BODY (99098)

ELECTRONIC WALL MOUNTED TAP

WATER EFFICIENT - CONNECTED TAPWARE ENABLED BY AWARE

TM

5

8

3

4

1

11

Fig. 3

9

92

1 9 4

1

2

6

10

7

5

Fig. 1

B

3 0

5 5 - 7 5

2 0

92

+5

 0

Trim excess mounting
box tiling flange after
tiling to be  flush with surface.

Fig. 2

Detail B

Isolation Valve in

closed position

Maximum hot water temperature : 80 C.

IMPORTANT

Pressure & Temperature Requirements.

New Regulation :-500 kPa maximum static pressure 

at any outlet within a building. (Ref. AS/NZS 3500.1)

Static inlet pressure range : 50 -700 kPa

Installation Requirements.

The installing plumber is responsible for waterproofing

all penetrations for Taps in Shower areas at installation

by a proprietary flange system or a sealant.(Ref AS3740)