background image

  installation 

  

4

  

5

  installation 

Before installing your new mixer, flush through the pipework to ensure removal of 
debris, turn off the water supply.
      

 Warning!

  Please check for any hidden cables and pipes before drilling holes in the 

wall.

The valve must be set into the wall (see dimension page). 
If you are fitting the valve to a partition wall or a wall of particularly soft substrate you 
will need specialist fixings.
Select the position for the shower valve and offer the shower valve to the wall, mark 
the 2 fixing points with a suitable pencil.  Remove the shower valve from the wall, drill 
the holes to a suitable depth for the wall plugs and secure with suitable screws.
Make all connections to the valve. Connect hot supply to left inlet of the valve and 
cold supply to right inlet.  
Connect the outlet (top) to the shower.

Slide the cover plate over the valve.

Push the control handle onto the body and secure with the grub screw using the 
supplied hexagonal key, fit the screw cover.

Cover 

plate

Valve

Control 

handle

Grub screw

Cover

42mm

Valve centre line

Valve fixing 

holes

22mm

Pipe connection centre line

Hot inlet

Cold inlet

Outlet to shower

Summary of Contents for synergie SYN145

Page 1: ... you the completed Guarantee Registration Form Vado accepts no responsibility for any forms lost in the post and returns by registered means is therefore recommended Under this guarantee which is non transferable Vado will at its option repair or replace free of charge any product or replacement part found to be defective The guarantee does not extend to any consequential loss or damage After repa...

Page 2: ...ement of Water Supply Water Fittings Regulations 1999 Schedule 2 Section 6 G15 13 2 Before making any inlet pipe connections all supply pipes MUST be thoroughly flushed to remove debris Failure to do so could result in damage or low flow from the mixer unit Water Supply Water Fittings Regulations 1999 Schedule 2 Section 4 G13 1 The fitting of isolating valves to the inlet feeds is advised for ease...

Page 3: ...m 64mm 22mm 99mm 130mm 185mm 90mm Operating Pressure Minimum operating pressure 0 5 bar Maximum operating pressure 5 bar Pull the handle out to increase the flow of water Turn the handle clockwise to increase the temperature and anti clockwise to decrease the temperature 50 75mm ...

Page 4: ...hower valve to the wall mark the 2 fixing points with a suitable pencil Remove the shower valve from the wall drill the holes to a suitable depth for the wall plugs and secure with suitable screws Make all connections to the valve Connect hot supply to left inlet of the valve and cold supply to right inlet Connect the outlet top to the shower Slide the cover plate over the valve Push the control h...

Reviews: