Installation - trim

Temperature handle (left)

  

Ensure the temperature handle is correctly 

located with the handle stop at 12 o’clock 

(see right). Screw the shroud assembly to 

the valve whilst holding the handle. 

Flow handle (right)

 

Screw the shroud assembly to the valve 

whilst holding the handle. Make sure 

that the handle mark is in the 12 o'clock 

position. 

Please note:

 if the handle/shroud 

assemblies do not align, remove the offset 

spline and replace the other way up (see 

right).

Handle stop at 

12 o’clock

Inside of 

temperature 

handle

The handset holder has slight adjustment. Guide the handset holder onto the 

spigot first and then slide the cover plate over the shrouds.

 Push the cover plate 

up to the wall and tighten the two grub screws on the underside of handset holder 

to secure it to the spigot. Apply a thin bead of silicone around the outside to seal 

against the tiled surface. 

13

Installation - handset

Handset outlet

 

Place a rubber washer into the nut end 

of the hose and attach it to the handset 

outlet (see above).

Handset

Place the other rubber washer into the 

cone end of the hose and screw to the 
handset 

(see right)

.

Rubber 

washer

Nut

Rubber 

washer

Handset

Cone end 

of hose

Flow 

Handle

Shrouds

Cover 

plate

Temperature 

Handle

Handset 

holder

Spigot

Shrouds

Handle 

mark

Offset 

spline

Summary of Contents for NOTION TAB-148/2WO-NOT-CP

Page 1: ...p for future reference Installation Guide NOTION where inspiration flows Vado Wedmore Road Cheddar Somerset England BS27 3EB tel 01934 744466 fax 01934 744345 aftersales vado com www vado com This ins...

Page 2: ...nd Scottish Byelaws 2004 For further information contact the Water Regulations department of your local water supplier see the WRAS website www wras co uk for details or the Water Regulations Advisory...

Page 3: ...4 5 Contents of Packaging Shower hose with 2 washers Handset Adaptors to x 3 Dimensions 95mm 80mm 40mm 80mm 285mm 125 5mm 75 100mm...

Page 4: ...6 7 Installation Quick guide 1 77mm 142mm 90mm 2 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 4 6mm Installation Quick guide 5 6 1 2 3 1 1 2 2 x 1 x 2...

Page 5: ...alve must be set into the wall between 75mm minimum 100mm maximum If you are fitting the valve to a partition wall or a wall of particularly soft substrate you will need specialist fixings Please cont...

Page 6: ...d Note outlet 2 will be connected to the handset Mortar guard 6mm hex key Mortar guard screws Spigot Cold inlet Hot inlet Outlet 1 Handset outlet Screw spigot into the outlet on the valve Tighten usin...

Page 7: ...older has slight adjustment Guide the handset holder onto the spigot first and then slide the cover plate over the shrouds Push the cover plate up to the wall and tighten the two grub screws on the un...

Page 8: ...thermometer when the handle mark is located at 12 o clock NOTE temperature readings should be taken at normal flow rate after allowing for the system to stabilise 2 If the temperature is not 38 procee...

Reviews: