13
12
Cleaning instructions
The electroplating on this product is finished to the highest standard. Due care needs
to be taken to ensure the appearance is retained.
We recommend cleaning all products with a soft damp cloth ONLY and advise strongly
against the use of all aggressive/corrosive cleaning products i.e. powders and liquids.
If these instructions are not followed, this may invalidate your guarantee in the event
of a problem occurring.
Commissioning
The valve has been factory set under balanced pressures and hot water supply at 65°C.
When your specific operating conditions are significantly different from the above, the
temperature of the water may vary from the setting.
When the difference is too great, you can adjust the calibration of the valve to suit
individual requirements of the installation:
1. Check the temperature of the water being delivered from the outlet with a
thermometer.
Note:
temperature readings should be taken at normal flow rate after allowing for the
system to stabilise.
2. If the temperature is not 38°C (When the 38º is aligned with the override button)
proceed to reset the calibration as follows.
Remove the handle: Prise out the cover, remove the screw and washer and pull off
the handle and spacer ring.
Ensure the step on the stop ring is located at 12 o'clock.
Do not remove the plastic stop ring. Turn the spline of the thermostatic valve clockwise
to decrease the temperature and anti-clockwise to increase the temperature until 38°C
is achieved at outlet.
Note:
the sensing part of the thermometer probe must be fully submerged in the water
that is to be tested.
Replace the spacer and handle making sure that the pin is against the step (see detail).
Once the handle has been attached ensure the temperature does not exceed 46°C when
turned entirely anti-clockwise.
Your valve setting is now commissioned.
Cover
Screw
Stop ring
Pin
Inside handle
Handle
Override
button
Valve splines
Step
Spacer ring
Summary of Contents for AXCES BOKX AX-BOK-149T-RRK-CP