background image

14

Maintenance

We advise that the below is carried out annually as failure to do so may result in 

invalidation of warranty.

Isolating the thermostatic valve
IMPORTANT:

 Please see the below procedure for isolating the thermostatic valve.

1. Isolate the incoming hot and cold water to the valve.
2. Turn shower valve on (left handle) to check isolation, please ensure that your body/

hands are not under the flow of water as there is a potential for delivery of hot water.
3. Remove temperature control handle and temperature stop ring (essential).
4. With shower in the on position, replace temperature handle on thermostatic Valve 

(ensure temp stop has been removed).
5. Turn temp handle fully anti clockwise until stop point is reached and can be turned no 

further , please ensure that your body/hands are not under the flow of water as there is 

potential for delivery of hot water if isolation has been unsuccessful.
6. Turn temperature handle fully clockwise until resistance is felt.  
7. If there is no flow of water coming from the outlet during both points 5 and 6 isolation 

has been successful, you may now remove and maintain the cartridge.
8. If at any of the above point’s water continues to flow please isolate at an alternative 

point within the system for both hot and cold and repeat points 2-8.

Filters

This thermostatic valve is fitted with a double filtering facility. 

Filters are fitted on the water inlets and on the thermostatic cartridge. 

Depending on the water quality, filters may become dirty, 

causing reduced flow and inefficient working of the valve.

Inlet filters

Check water has been isolated. Undo both locking nuts at the back of the valve and 

remove from the wall. Pull out the filter/washer, rinse in water to remove the dirt, and 

then soak them in vinegar or descaling agent.

Thermostatic cartridge

To clean the filters, you must first remove the cartridge from the housing.
Removing the Cartridge: 

1. Check water has been isolated. 

2. Remove the stop ring 

3. Using a suitable spanner remove the thermostatic cartridge. 

4. Clean filters by rinsing them under running water to remove any debris. 

5. If there is limescale deposits then it is recommended to immerse the cartridge for a 

few minutes in 50% white v 50% hot water, brush the filters gently and then rinse 

under running water to clean all particles. If this is not effective, a replacement cartridge 

should be fitted.

15

Maintenance

Cover

Screw

Stop ring

Pin

Inside handle

Handle

Override 

button

Valve splines

Step

Spacer ring

6. Before reassembling the cartridge, clean its housing with a wet cloth and grease the 

‘O’ rings using a suitable silicone grease. 

7. Reassemble the cartridge into the body, then place the plastic stop ring onto the 

cartridge with the step at the 12 o’clock position. 

8. Turn on the water supply. 

9. Check the water temperature to ensure correct commissioning. 

See page 13 of this guide for commissioning. 

10. Ensure that the step on the stop ring is at 12 o’clock and replace the handle with 

the temperature override button also pointing at 12 o’clock being careful not to turn the 

spline of the valve.

Summary of Contents for AXCES BOKX AX-BOK-149T-RRK-CP

Page 1: ...rs model AX BOK 149T RRK CP Version 1 1 8 19 VADO Wedmore Road Cheddar Somerset England BS27 3EB tel 01934 744466 fax 01934 744345 www vado com sales vado com SHOWER COLUMN KEEP FOR FUTURE REFERENCE I...

Page 2: ...egulations department of your local water supplier see the WRAS website www wras co uk for details or the Water Regulations Advisory Scheme by email info wras co uk or telephone 01495848454 Before mak...

Page 3: ...4 5 Contents of Packaging Handset Riser rail Shower hose with 2 washers Riser arm with wall bracket Shower head with washer Dimensions 950 1150mm 395mm 200mm 150mm 30mm 65mm 25mm 282mm...

Page 4: ...of the riser to suit your requirements This must be done before installing the riser rail Carefully push the riser arm down into the riser rail being careful not to damage the seals Make sure that the...

Page 5: ...riser bracket against the wall slide the bracket down and clip it into the wall bracket fig 2 Finally tighten the grub screw on the side of the riser to secure the riser to the valve fig 3 Fig 1 Rise...

Page 6: ...handset turning the handle away will operate the shower head Hot Cold Handset Shower head Pushing down on this button will override the set temperature Operation Release the handle on the handset hol...

Page 7: ...rom the outlet with a thermometer Note temperature readings should be taken at normal flow rate after allowing for the system to stabilise 2 If the temperature is not 38 C When the 38 is aligned with...

Page 8: ...pending on the water quality filters may become dirty causing reduced flow and inefficient working of the valve Inlet filters Check water has been isolated Undo both locking nuts at the back of the va...

Page 9: ...16 Notes 17 Notes...

Page 10: ...one to our aftersales team Registration must be completed within 6 months from date of purchase Under the extended guarantee period VADO will at its option offer to supply any replacement product or c...

Reviews: