CLIO Diagnostics
4.5. ON/S
USPEND
B
UTTON
I
NOPERATIVE
(P
ROCEDURE
5)
Open unit to Tablet mode and
see if it powers up. (if the
user previously set this
option, the unit may power
on)
Power?
Y
N
Verify unit remains powered
up.
Power?
Go To Procedure 3
Go To Procedure 2
Replace Display Connection
FPC
Fixed?
Go To Final Test
Procedure
Replace Inverter PWB Unit
Fixed?
Replace Main PWB
Y
N
Y
N
Y
N
4-5
The information contained in this document is confidential and the sole property of Vadem Inc. Written
permission must be obtained to reprint or use any of this information.
AUTHORED BY ANTHONY HERNANDEZ - (415)786-2081 - [email protected]