background image

Quick-Connect CCU Kit for BRC-H900 Camera 

 

© 2012 Vaddio - All Rights Reserved.  Document Number 342-0507 Rev A                                                                                    Page 13 of 16

 

 

Compliance and CE Declaration of Conformity - Quick-Connect CCU and EZIM CCU 

 
 

Compliance testing was performed to the following regulations: 

 

FCC 

Part 

15, 

Subpart 

      Class 

 

ICES-003, 

Issue 

4: 

 

2004 

      Class 

 

European Standard EN 55022 A:  1998 + A1: 2000  

 

 

 

Class A 

 

European Standard EN 55024:  1998 + Amendments A1:  2001 + A2:  2002   

Class A 

 

EMC 

Directive 

89/336/EC 

      Class 

 

 
 

FCC Part 15 Compliance 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15, Subpart 
B, of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference when the 
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy 
and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the 
user will be required to correct the interference at his/her own expense. 
 
Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must 
accept any interference including interference that may cause undesired operation of the device. 
Changes or modifications not expressly approved by Vaddio can affect emission compliance and could void the user’s 
authority to operate this equipment. 
 
 
 

ICES-003 Compliance 

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio 
Interference Regulations of the Canadian Department of Communications.   
Le présent appareil numérique n’emet pas de bruits radioélectriques dépassant les limites applicables aux appareils 
numeriques de la classe A préscrites dans le Règlement sur le brouillage radioélectrique édicte par le ministère des 
Communications du Canada. 
 
 

 

European Compliance 

This product has been evaluated for Electromagnetic Compatibility under the EMC Directive for Emissions and Immunity and 
meets the requirements for a Class A digital device.  In a domestic environment this product may cause radio interference in 
which case the user may be required to take adequate measures.   

 
Standard(s) To Which Conformity Is Declared: 
EMC Directive 89/336/EC 

 

EN 55022 A:  1998 + A1: 2000  

 

 

 

 

Conducted and Radiated Emissions

 

EN 55024:  1998 + Amendments A1:  2001 + A2:  2002

  

 

Immunity 

 

EN 

61000-4-2: 

     Electrostatic 

Discharge 

 

EN 

61000-4-3: 

     Radiated 

Immunity 

 

EN 

61000-4-4: 

     Electrical 

Fast 

Transients 

 

EN 

61000-4-5: 

 

 

     Surge 

Immunity 

 

EN 

61000-4-6: 

     Conducted 

Immunity 

 

EN 

61000-4-8: 

     Power 

Frequency 

Magnetic 

Field 

 

EN 

61000-4-11 

     Voltage 

Dips, Interrupts and Fluctuations 

 
 

Please see the Sony manual for compliance information on the BRC-H900 PTZ Camera. 

Summary of Contents for Quick-Connect CCU H900

Page 1: ...IEW CCU H900 camera Included Part Numbers without Camera 998 6897 000 Quick Connect CCU Kit for the BRC H900 Camera camera not included North America 998 6897 001 Quick Connect CCU Kit for the BRC H90...

Page 2: ...Quick Connect CCU Kit for BRC H900 Camera 2012 Vaddio All Rights Reserved Document Number 342 0507 Rev A Page 2 of 16 Inside Front Cover Blank...

Page 3: ...Connect CCU Front Panel Controls left to right 6 Image Magnification of control Buttons and Rotary Encoders from left to right 6 Image Rear Panel Connections and Controls left to right 7 Image EZIM CC...

Page 4: ...Connect CCU H900 Kit without the camera Important Safeguards Read and understand all instructions and warranty statements before using Do not operate any device if it has been dropped or damaged In t...

Page 5: ...Connect CCU Kit NO CAMERA for the BRC H900 Camera International Carefully remove the device s and all parts from the packaging Please do not toss the packaging yet just set it aside where it won t be...

Page 6: ...into microprocessor memory When lit backlit blue SPDT switch the scene is activated To store a scene the user adjusts the camera and then touches and holds the scene button down until the button blin...

Page 7: ...black burst generators to externally sync the cameras This input is transmitted through a differential amplifier to a receiver at the EZIM CCU The G L gain adjustment is on the EZIM CCU or the receiv...

Page 8: ...bracket All cabling is routed to the head end using Cat 5 cables using standard straight through RJ 45 connectors 568B termination Pass thru type RJ 45 connectors should never be used Before Installin...

Page 9: ...ll Mount Image Heavy duty wall mount The wall mount may be mounted directly to a 3 gang wall box or to drywall with the appropriate wall anchors Step 2 Connect the break out cable to the EZIM CCU Moun...

Page 10: ...mount interface that breaks out the signals from the Cat 5 cables back to the standard connectors Connect the other side of the appropriate Cat 5 cable to the CCU except for power The basic system co...

Page 11: ...ill have a grainy video image Adjust the detail settings for a smoother image Adjust Color to Taste Required adjustments will vary based on the environment The CCU allows the set up of several scenes...

Page 12: ...nt request an RMA from Vaddio s technical support Provide a technician with a return phone number e mail address shipping address and product serial numbers and describe the reason for repairs or retu...

Page 13: ...at may cause undesired operation of the device Changes or modifications not expressly approved by Vaddio can affect emission compliance and could void the user s authority to operate this equipment IC...

Page 14: ...Power 7 Power 8 Power RS 232 IN Connector RJ 45 Pin Signal RS 232 1 Not Used 2 Not Used 3 Not Used 4 Not Used 5 Not Used 6 GND 7 RXD from TXD 8 TXD to RXD RS 232 G L OUT Connector RJ 45 Pin Signal RS...

Page 15: ...CVBS 2 CVBS GND CVBS GND 3 Y Y 4 C PB 5 C GND PB GND 6 Y GND Y GND 7 Not Used PR 8 Not Used PR DB 25 Connector Pins Signal 1 CVBS GND 14 CVBS 2 G L GND 15 G L 3 NC 16 GND IN 4 TXD IN 17 RXD IN 5 NC 1...

Page 16: ...1 4464 www vaddio com 2012 Vaddio All Rights Reserved Reproduction in whole or in part without written permission is prohibited Specifications and pricing are subject to change without notice Vaddio Q...

Reviews: