![VADA VFB-S75 Installation Manual Download Page 7](http://html1.mh-extra.com/html/vada/vfb-s75/vfb-s75_installation-manual_3145365007.webp)
INTERPRETING THE APC
VFB-APC
Error
Pump on
Power on
Restart
1~240V 50 Hz
Max 1.5kW 10A
Max 65°C
IP65
Max 1MPa (10 bar)
AUTO PRESSURE CONTROL
VFB-APC
Error
Pump on
Power on
Restart
1~240V 50 Hz
Max 1.5kW 10A
Max 65°C
IP65
Max 1MPa (10 bar)
AUTO PRESSURE CONTROL
VFB-APC
Error
Pump on
Power on
Restart
1~240V 50 Hz
Max 1.5kW 10A
Max 65°C
IP65
Max 1MPa (10 bar)
AUTO PRESSURE CONTROL
VFB-APC
7
Green light
The VFB-APC is connected to the power
supply successfully.
Yellow light
The pump is in operation.
Note:
On initial start up the pump will run until
the supply line is primed to remove all air.
Red light
Flashing red: Loss of flow detected. While the
red light is flashing, the pump will remain on for
20 seconds, then turn off as it tries to re-prime
itself. It will attempt this several times.
Solid red: The pump has not been able to
detect water and cannot re-prime itself. The
pump will turn off for 24 hours, or until reset.
To reset, turn the power off, then on or
press the restart button.