Fire and burn hazard. Modern motors run at high
temperatures. To reduce risk of fire, do not allow
leaves, debris, or foreign matter to collect around
the pump motor. To avoid burns when handling
the motor, let it cool for at least 20 minutes before
trying to work on it. A thermal overload switch pro-
tects the motor for heat damage during operation.
DO NOT RUN PUMP DRY
Ensure that your pump is primed before operating
The pump operator or owner must be provided
with this owner’s manual. This must be read before
operation, and followed during operation.
Ensure that your pump is filled with water before
operating.
The pump is designed to be used with clean water
in a residential application. Do not use it with
alternative fluids, specifically abrasive, corrosive
or explosive fluids. Do not install or operate your
pump in an explosive enviroment or near
combustible matter.
OPERATION
START-UP/OPERATION
Open all valves in the suction and discharge lines. When the power is turned on, the pump will start to pump water. Without an Auto Pressure
Control or Mains Water Switch-Over Device, the pump will continue to operate until the power is switched off.
Most applications will incorporate an Auto Pressure Control or Mains Water Switch-Over Device which will stop the pump as soon as it has
pressurised the system it is connected to. For instructions on operating your pump with one of these devices, please refer to the manual that
came with your unit.
The system is now ready for use. If no water is delivered, check the troubleshooting section.
VADA - V110-H
ELECTRICAL INSTALLATION
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.
The pump must be supplied by an outlet protected
by a residual current device or earth leakage circuit
breaker with a maximum rated residual current of
30mA
The pump is supplied with:
•
A fixed cable featuring a weatherproof IEC socket
•
A separate power cable which features a weatherproof IEC plug and a standard Australian 10 amp plug.
If connecting directly to a power outlet, simply connect the two supplied cords using the IEC socket and plug. If you are installing a Vada Auto
Pressure Control or a Mains Water Switch Over Device, connect the IEC socket from the pump to the IEC plug cord on the device.
Ensuring there are no water traces on the connectors push them firmly into each other to ensure intended splash (water) proof protection. This
connection shall be separated again only for service purpose and only after the power supply is removed by unplugging the cord form the socket
outlet. The socket outlet shall be in dry and flood free location; preferably do not use extension cords for this very reason and because they can
cause voltage drop. Supply voltage outside limits specified in Model Data can cause motor overheat leading to overload tripping, reduced
component life or seriously damage pump and voids warranty.
For additional protection, the pump must be supplied from an outlet protected by a residual current device – RCD (also known as an Earth
Leakage Circuit breaker – ELCB) with a maximum rated residual current of 30mA.