Fire and burn hazard. Modern motors run at high 

temperatures. To reduce risk of fire, do not allow 

leaves, debris, or foreign matter to collect around 

the pump motor. To avoid burns when handling 

the motor, let it cool for at least 20 minutes before 

trying to work on it. A thermal overload switch pro-

tects the motor for heat damage during operation.

DO NOT RUN PUMP DRY

Ensure that your pump is primed before operating

The pump operator or owner must be provided 

with this owner’s manual. This must be read before 

operation, and followed during operation.

Ensure that your pump is filled with water before 

operating.

The pump is designed to be used with clean water 

in a residential application. Do not use it with 

alternative fluids, specifically abrasive, corrosive 

or explosive fluids. Do not install or operate your 

pump in an explosive enviroment or near 

combustible matter.

OPERATION

START-UP/OPERATION

Open all valves in the suction and discharge lines.  When the power is turned on, the pump will start to pump water.  Without an Auto Pressure 

Control or Mains Water Switch-Over Device, the pump will continue to operate until the power is switched off.

Most applications will incorporate an Auto Pressure Control or Mains Water Switch-Over Device which will stop the pump as soon as it has 

pressurised the system it is connected to. For instructions on operating your pump with one of these devices, please refer to the manual that 

came with your unit.

The system is now ready for use. If no water is delivered, check the troubleshooting section.

VADA - V110-H

ELECTRICAL INSTALLATION

This appliance is not intended for use by persons 

(including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision 

or instruction concerning use of the appliance by a 

person responsible for their safety.

The pump must be supplied by an outlet protected 

by a residual current device or earth leakage circuit 

breaker with a maximum rated residual current of 

30mA

The pump is supplied with:

• 

A fixed cable featuring a weatherproof IEC socket

• 

A separate power cable which features a weatherproof IEC plug and a standard Australian 10 amp plug.

If connecting directly to a power outlet, simply connect the two supplied cords using the IEC socket and plug.  If you are installing a Vada Auto 

Pressure Control or a Mains Water Switch Over Device, connect the IEC socket from the pump to the IEC plug cord on the device.

Ensuring there are no water traces on the connectors push them firmly into each other to ensure intended splash (water) proof protection. This 

connection shall be separated again only for service purpose and only after the power supply is removed by unplugging the cord form the socket 

outlet. The socket outlet shall be in dry and flood free location; preferably do not use extension cords for this very reason and because they can 

cause voltage drop. Supply voltage outside limits specified in Model Data can cause motor overheat leading to overload tripping, reduced 

component life or seriously damage pump and voids warranty.

For additional protection, the pump must be supplied from an outlet protected by a residual current device – RCD (also known as an Earth     

Leakage Circuit breaker – ELCB) with a maximum rated residual current of 30mA.

Summary of Contents for V110-H

Page 1: ...V110 H Multistage Pump Instruction Manual...

Page 2: ...tion Single phase power supply with capacitor permanently acti vated and thermal protection built into the motor winding Thermal protection built into the motor winding Speed of rotation 2850 rpm Suit...

Page 3: ...r Voltage Amp F Q L 1 0 20 40 60 80 100 HP kW HP kW m3 h 1 2 2 4 3 6 4 8 6 V110 H 1 2 0 9 1 7 1 25 1 230V 5 8 20 Discharge head in meters 60 55 48 36 26 10 Model Dimensions mm Weight A B C D Suction P...

Page 4: ...work on it A thermal overload switch protects the motor from heat damage during operation If the supply cord is damaged it must be replaced by the manufacturer it s service agent or similarly qualifie...

Page 5: ...When pumping from a well pit etc a foot valve should be installed on the suction pipe Optional Fitted with a suction Strainer Filter In line strainers filters are only recommended for pumps fitted wi...

Page 6: ...LECTRICAL INSTALLATION This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have be...

Page 7: ...ect is blocking the impellers Call 1800 032 566 for your nearest Reece branch The liquid is too thick Call 1800 032 566 for your nearest Reece branch You may need a different type of pump VADA V110 H...

Page 8: ...istered trade people The manufacturer distributor reserves the right to vary specifications or delete models from their range without prior notification Dimensions and set outs listed are correct at t...