CONSTRUCTION

Pump Casing

X5 CrNi 1810 (AISI 304) stainless steel

Motor Bracket

Die-cast aluminium

Impeller

Technopolymer with X5 CrNi 1810 (AISI 

304) stainless steel shim ring

Diffusors

Technopolymer

Shaft

X12 CrNiS 1809 (AISI 416) stainless steel

Mechanical Seal

Graphite

Counterface

Ceramic

Seal Holder Plate

GFN2V Noryl

O-ring

NBR 70 Shore

PRODUCT OVERVIEW

The VADA horizontal multistage centrifugal pumps combine the 

functional benefits of centrifugal pumps and the practical benefits 

of self priming pumps.  They warrant high hydraulic and suction 

performances.

USAGE LIMITATIONS

• 

Type of liquid: clean water with no suspended solids or abrasive 

material

• 

Maximum liquid temperature: 50

O

C

• 

Maximum/Minimum ambient temperature: 40

O

C / 5

O

C

• 

Maximum recommended suction height: 7m with foot valve

• 

Maximum operating pressure: 7 bar

VADA - V110-H

MOTOR

• 

Enclosed, externally ventilated

• 

Level of protection IP44

• 

Class F insulation

• 

Single phase power supply with capacitor permanently acti-

vated and thermal protection built into the motor winding

• 

Thermal protection built into the motor winding

• 

Speed of rotation 2850 rpm

• 

Suitable for continuous use

WARRANTY

You have purchased a quality product from Reece Australia. This 

product is covered by a 24 month warranty. This warranty covers faults 

in the product construction, material and assembly. Faulty products 

will be repaired or exchanged free of charge. Faulty items become our 

property.

This warranty does not include faults caused by

• 

Unsuitable or improper use

• 

Incorrect installation

• 

Normal wear and tear

• 

Inadequate or complete lack of maintenance

• 

Chemical, electrochemical or electrical influences

To the maximum extent permitted by law, Reece excludes all warranties 

other than those set out above. In the event of a warranty claim, we 

will replace or repair defective products, or pay for the cost of having 

defective products repaired or replaced, but will not be liable for any 

injury to any person, damage to any property, any indirect or 

consequential loss, or in any other respect.

Summary of Contents for V110-H

Page 1: ...V110 H Multistage Pump Instruction Manual...

Page 2: ...tion Single phase power supply with capacitor permanently acti vated and thermal protection built into the motor winding Thermal protection built into the motor winding Speed of rotation 2850 rpm Suit...

Page 3: ...r Voltage Amp F Q L 1 0 20 40 60 80 100 HP kW HP kW m3 h 1 2 2 4 3 6 4 8 6 V110 H 1 2 0 9 1 7 1 25 1 230V 5 8 20 Discharge head in meters 60 55 48 36 26 10 Model Dimensions mm Weight A B C D Suction P...

Page 4: ...work on it A thermal overload switch protects the motor from heat damage during operation If the supply cord is damaged it must be replaced by the manufacturer it s service agent or similarly qualifie...

Page 5: ...When pumping from a well pit etc a foot valve should be installed on the suction pipe Optional Fitted with a suction Strainer Filter In line strainers filters are only recommended for pumps fitted wi...

Page 6: ...LECTRICAL INSTALLATION This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have be...

Page 7: ...ect is blocking the impellers Call 1800 032 566 for your nearest Reece branch The liquid is too thick Call 1800 032 566 for your nearest Reece branch You may need a different type of pump VADA V110 H...

Page 8: ...istered trade people The manufacturer distributor reserves the right to vary specifications or delete models from their range without prior notification Dimensions and set outs listed are correct at t...