you regularly clean and thoroughly dry the adapter, especially after 
using it on bags containing liquids. 
Do not attempt to detach the tube from the adapter.
For full instructions, see chapter xx Need to know how to preserve 
your food in the Vacuumbags?  See Chapter xx

Plug and play // Containers 

Quick check Containers
-   Put the lid on the container. 
-   Place the vacuum adapter on the desig-

nated area (picture)

-   Touch in the middle of the circular LED 

rings and the Home Base will start remov-
ing air from the container via the vacuum 
adapter. During the vacuum process, the 
light rings blink to indicate that the vacuum is being created.

-   Press the adapter firmly on the container for about 5 seconds.  

-  At first time use, or after replacing the seal in the lid, it might take 

a little longer to create vacuum in the containers. Indication of 
vacuum time of an empty container: 
-  1L: +- 30 seconds 
- 2L: +- 45 seconds 
- 4L: +- 90 seconds 

-   The pump will automatically switch off after the vacuum level has 

been reached. The circular LED rings however will remain switched 
on to enable you to vacuum another container or bag.

-   To release the vacuum from the container, gently pull the grey valve 

on the top of the lid. You will hear the air release. When all vacuum 
is released you can take the lid from the container. 

Need to know how to preserve your food in the Containers?  
See Chapter xx
For full instructions, see chapter xx for more functionalities Containers

Plug and play // Vacuumbags 

-   Remove all packaging and foils from the 

vacuum hose and vacuum adapter. Some 
parts of product packaging are eligible 
for recycling. Keep packaging away from 
small children.

-   Connect the vacuum tube to the vacuum 

adapter (picture)

-   Simply plug the free end of the vacuum tube in the Home Base and 

press– the circular indicator LED light rings will light up when the 
vacuum tube is attached properly (picture)

Quick check Vacuum adapter:
-   Place the adapter on the black top of 

the Vacuvita Homebase and touch in the 
middle of the circular LED rings and the 
Home Base will start removing air via the 
vacuum adapter. During the vacuum pro-
cess, the light rings blink to indicate that 
the vacuum is being created. 

-   The pump will automatically switch off 

after the vacuum level has been reached. 
The circular LED rings however will remain switched on to enable 
you to vacuum another container or bag:

-   Make sure no liquids enter the vacuum tube: always check that the 

vacuum adapter is dry before use (Warranty)

-   Please note that the LED rings will switch off after 15 minutes. 

Quick check Vacuumbags
-   Close the bag with the ziplock
-   Place the vacuum adapter on the desig-

nated area. (picture)

-   Touch in the middle of the circular LED 

rings and the Home Base will start 
removing air from the vacuum bag via 
the vacuum adapter. During the vacuum 
process, the light rings blink to indicate 
that the vacuum is being created.

-   Press the adapter firmly on the bag dur-

ing the vacuum process. 

 

-  If the Homebase switches off while there 

is still air in the bag, please retry, the adapter might have been 
misaligned.

 

-  If you don’t see any air removing from the bag, please be patient 

it may take a while before the bag is wrapped. Otherwise check 
again if your ziplock is closed properly and retry. 

-   The pump will automatically switch off after the vacuum level has 

been reached. The circular LED rings however will remain switched 
on to enable you to vacuum another container or bag.

-   To release the vacuum from the bag, gently open the ziplock on the 

top of the bag. 

During the vacuum process small crumbs, food particles or drops of 
liquid may be pulled into the vacuum system. It is recommended that 

Summary of Contents for Home Base

Page 1: ...www vacuvita com For Vacuvita Home Base vacuum containers and vacuum bags Manual quick reference guide...

Page 2: ...your food within seconds The springs and dampers are perfectly balanced for smooth opening and one handed closing of the cover Creating a vacuum is as easy as closing the lid Your Vacuvita system can...

Page 3: ...er the grill Important safety instructions Please carefully read this user manual before using this product and keep it for future reference When using your Vacuvita products always take basic precaut...

Page 4: ...er Vacuvita products are not a substitute for refrigeration or freezing Perishables still need to be kept in the refrigerator or freezer Vacuum packaging is not a substitute for canning Always allow f...

Page 5: ...picture Simply plug the free end of the vacuum tube in the Home Base and press the circular indicator LED light rings will light up when the vacuum tube is attached properly picture Quick check Vacuu...

Page 6: ...18 Vacuum bags Using the Vacuvita Home Base 19 with vacuum bags Cleaning the vacuum adapter 20 Vacuum containers Using the Vacuvita Home Base 21 with vacuum containers How to scan your containers 22...

Page 7: ...tomatically open the lid and release the vacuum 3 Blue indicator light 4 Home Base lid 5 Adapter socket with removable cap 6 Circular indicator LED light rings 7 Capacitive touch control to enable the...

Page 8: ...he power plug from the wall socket In case of an emergency or system malfunction the vacuum can be released by pressing the emergency vacuum release switch Turn the Vacuvita Home Base so the back is f...

Page 9: ...Insert the free side of the adapter hose into the vacuum socket The LED light rings will switch on below the Home Base lid Place the vacuum adapter on the marked area around the valve of the vacuum ba...

Page 10: ...cleaned Do not use the bags for different raw products after each other Always apply proper hygienic precautions to prevent foodborne illness For an optimal vacuum process with liquids such as freshl...

Page 11: ...injuries from exposure You can heat cooked foods such as leftovers in a Vacuvita bag using a microwave The bag should not be used to microwave raw foods Always open the bag prior to putting it in a mi...

Page 12: ...ils Gently slide the filter back after cleaning SECTION A A SCALE 2 1 Cleaning or replacing the removable air filter Occasionally you may need to clean or replace the air filter on the outside of the...

Page 13: ...losed Check if there are no holes or tears in the bag This means Possible solutions Pump does not switch on Light does not switch on There is no electrical connection between the lid magnet and steel...

Page 14: ...his product with non Vacuvita parts or accessories Furthermore this Limited Warranty does not cover Acts of God such as fire flood hurricanes and tornadoes This Limited Warranty shall not be deemed to...

Page 15: ...www vacuvita com Vacuvita B V Orionstraat 15 2516 AS The Hague The Netherlands Designed to suit your taste...