1 . Power the Unit On
- Plug in the unit. The LED displays and indicator lights will
be on for 2 seconds, and then the 3-digit LED display will display "on" (if the
vacuum lid is closed, the LED display will display "CLO"). Finally, the unit will
enter the work preparation mode.
2 . Setting Vacuum Time
- In the work preparation mode, press the "Set" button.
The "Vacuum" light will come on. Press the "Up / Down" buttons and the 3-digit
LED display will raise or lower the vacuuming time by 5 seconds (press and
hold for faster adjustment). The time range for vacuuming is 5-90 seconds.
3 . Setting Gas Time
- In the vacuum time setting mode, press the "Set" button.
The "Gas" light will come on. Press the "Up / Down" buttons and the 3-digit
LED display will raise or lower the gas time by 0.5 seconds (press and hold for
faster adjustment). The time increments for gas are 0 – 10 (0 – 5 seconds).
4 . Setting Sealing Time
- In the vacuum time setting mode, press the "Set"
button. The "Sealing" light will come on. Press the "Up / Down" buttons and the
3-digit LED display will raise or lower the sealing time by 0.5 seconds (press
and hold for faster adjustment). The time range for sealing is 0-6 seconds.
5 . Setting Cooling Time
- In the sealing time setting mode, press the "Set"
button. The "Cooling" light will come on. Press the "Up / Down" buttons, and the
3-digit LED display will raise or lower the cooling time by 0.5 seconds (press and
hold for faster adjustment). The time range for cooling is 0-5 seconds.
6 . Setting "Marinate" Mode
- Press the "Marinate" button and the "Marinate" light
will come on. Select the "Marinate" mode, then press the "Up / Down" buttons.
The 3-digit digital will raise or lower the marinate time by 9 minutes (press and
hold for faster adjustment). The marinate time range is 9-99 minutes. If you press
the "Marinate" button again, the "Marinate" mode will go off.
7 . Select the Preset Program
- Press the "Prog 0-9" button and the "Prog 0-9"
light will come on. The corresponding program number will be displayed in the
1-digit LED display, and the vacuum time or sealing time will be displayed in
the 3-digit LED display. Press "Prog 0-9" again, and the 1-digit LED display will
display the number to adjust by 1 (press and hold for faster adjustment). The
range of programs is 0-9.
8 . Reset the Preset Program
- When selecting the preset program in step 6,
press the "Set" button to set relevant parameters, and press the "Set-Prog"
button again. The machine will emit a "beep" and reset the preset program
successfully.
9 . Vacuum & Sealing
- In the "Vacuum & Sealing" mode, close the lid and the
"Vacuum" light will flash. The pump will work and the LED display will begin
to count backwards by 1 second. After finishing the count down, the vacuum
pump will turn off, and the machine will enter the "Sealing" mode. The
programming instructions
6