I/O-expander board installation (Vacon CXS-range)
Vacon Plc
Tel:
+358-201 2121
Fax:
+358-201 212 205
Service:
+358-40-8371 150
E-mail:
[email protected]
http://www.vacon.com
1
3
I N S TA L L AT I O N
3.1.
G e n e r a l
Check that your have received all the required parts (Figure 3-1):
- I/O-repeater board (1) and I/O-pole shielded data cable (2)
- check that you have also received the jumper for I/O- repeater board
terminal X5 (3)
- 4-pole power cable (4)
- protection foil below (5) and above (6) the I/O-reapeater board
- stand sleeve (7)
- screw for fixing I/O-repeater board (8)
- 12-pole communication cable (9)
- opition box (10)
- I/O-expander board (11) (check that the typecode is corresponds to
your order)
- I/O-interface board (12)
- 10-pole data cable (13)
- 4-pole power cable (14)
- screws for I/O-expander board (15)
- screws for I/O-interface board (16)
Figure 3-1. I/O-expander board parts.
If the delivery does not match your order, please contact the supplier immediately. Only
a competent electrician should carry out the electrical installation.
Before doing any commissioning, carefully read the safety instructions in the "USER'S
MANUAL, VACON CX/CXL/CXS", Chapter 1, SAFETY.
Disconnect the frequency converter from the mains. NOTE: Also the control circuits!
Wait further 5 minutes before opening the cover of the frequency converter. Verify by
measuring that the frequency converter is safe to touch.