4.
Inspect the pouch
When the lid opens, remove and inspect the pouch.
Vacuum confirmation -
Check the quality of the vacuum by looking at
the tightness of the pouch and the product. Look for air pockets or air
leaks. If you notice that the product is not vacuum packaged tightly,
then increase the vacuum time by 5 seconds and vacuum and seal
again.
Seal confirmation –
Inspect the pouch seal. A positive seal will appear
clear upon inspection. If the seal is spotty or incomplete, increase the
seal time by 0.1 second. If the seal appears white or milky, decrease
the seal time by 0.1 second. Once the settings are determined for your
application, vacuum and seal again.
If the product is vacuumed and sealed tightly, the process is complete.
How to Use
Summary of Contents for VP321