Vacmaster VP215 User Manual Download Page 7

www.VacMasterFresh.com • 800-821-7849

6

HOW TO

Set Up - Adding Oil to the VP215

Please read all instructions before operating the VP215.

IMPORTANT:

 Oil must be added to machine prior to use. Make 

sure the VP215 is turned OFF and unplugged before adding oil.

Required Supplies:

    ½ quart of VACMASTER

®

 machine oil

    Empty oil bottle with spout
    Phillips head screwdriver 
    Adjustable wrench (not included)

1.  Prepare the oil

 - The VP215 includes a maintenance kit that 

contains a ½ quart of oil and an empty oil bottle with spout.  Fill 
the empty oil bottle with oil.

2.  Remove the back panel 

- Using the enclosed Phillips head 

screwdriver, remove the four screws from the back panel and 
take the panel off the machine.

3.  Remove the oil fill bolt 

- Locate the oil fill bolt on the vacuum 

pump and remove it using an adjustable wrench or similar tool.

4.  Fill the pump with oil

 - Insert the spout into the open hole (oil 

fill bolt opening) and begin pouring the oil into the pump.  Fill 
the pump until the oil level is at ½ to ¾ in the site glass. This is 
approximately 3 - 3½ ounces of oil.  

5.  Replace the oil fill bolt and back panel

 - Once the pump is 

filled with oil, screw the oil fill bolt back in place and put the back 
panel on the machine.  

The VP215 Chamber Vacuum Sealer is now ready for use.

Back of 

Housing  

Cabinet

Oil Fill Bolt

Oil Site  
Glass

Summary of Contents for VP215

Page 1: ...v 2015 04 09 Register your product and get support at www VacMasterFresh com User s Manual VP2 1 5 Models VP215 110V VP215EU 220 240V...

Page 2: ...t will never leave your countertop The VP215 is a chamber vacuum system which offers two distinct advantages over non chamber external suction units First a much higher level of vacuum can be achieved...

Page 3: ...he VP215 if it has a damaged cord or plug 7 Do not operate the VP215 if it malfunctions or is damaged Contact Customer Service at 800 821 7849 8 Use the VP215 only for its intended use 9 Closely super...

Page 4: ...prevent this from occuring Delicate foods can be frozen prior to packaging to protect them from getting crushed by the vacuum Use VacMaster Bone Guards to cover an item s sharp edges to prevent pouch...

Page 5: ...ler Plates Used to occupy space in the chamber The plates allow for faster vacuum When more space is occupied there is less air to be removed from the chamber 6 Seal Bar 7 Lid Lock This feature is use...

Page 6: ...using the UP DOWN Buttons Cooling Illuminates to adjust vacuum time as well as during the cooling process During set up adjust the cooling using the UP DOWN buttons 2 Working Indicator Light Illumina...

Page 7: ...the back panel Using the enclosed Phillips head screwdriver remove the four screws from the back panel and take the panel off the machine 3 Remove the oil fill bolt Locate the oil fill bolt on the vac...

Page 8: ...l will illuminate showing a symbol Set Up Adjusting the VP215 Timing Controls Note All timing adjustments must be made with the lid lock off and the lid open To adjust set the timing controls press th...

Page 9: ...se the sealing time press the SET button until SEALING is illuminated and then use the UP DOWN buttons to adjust the sealing time to accommodate your application It is recommended that you make adjust...

Page 10: ...er pouches up to 10 W x 13 L in size 2 Fill the pouch and place inside the chamber Fill the pouch with the product to be vacuum packaged and place the pouch inside the chamber Keep pouches that contai...

Page 11: ...that the product is not vacuum packaged tightly then increase the vacuum time by 5 seconds and vacuum and seal again Seal confirmation Inspect the pouch seal A positive seal will appear clear upon in...

Page 12: ...an dry and free of debris for the vacuum process to be successful Wipe surface of the seal bar lid gasket and the inside of the pouch and try again Vacuum pouch loses vacuum after being sealed Sharp i...

Page 13: ...or spray directly with liquid Check the Vacuum Chamber and Gasket making sure they are clean and free of debris If needed use a clean damp cloth with mild soap a Wipe the vacuum chamber clean b Wipe t...

Page 14: ...re vacuum packaging helps prevent this from occuring NOTE Due to the risk of anaerobic bacteria soft cheeses fresh mushrooms garlic and onions should never be vacuum packaged It is critical that food...

Page 15: ...0 821 7849 PARTS Parts Information 14 No Description Qty Part Number 1 Lid Screws 4 2 Upper Plate for Lid 2 3 Lid 1 979201 4 Lower Plate for Lid 2 5 Lid Gasket 1 979425 6 Holder for Seal Pad 1 979225...

Page 16: ...www VacMasterFresh com 800 821 7849 PARTS Parts Information 15...

Page 17: ...t Filter 1 19 Relay Contactor 1 979141 20 Solenoid Valve Pack 1 979261 21 Seal Transformer 1 979240 22 Chamber Support Arm 1 23 Control Transformer 1 979139 24 Support Arm Spring 1 25 Solenoid Valve H...

Page 18: ...ge 2 7 Roller Pin 2 8 Hinge Connecting Eye 2 9 Hexagon Hinge Stop 2 10 Roller 2 11 Bumper Hinge 2 12 Screw 2 13 Plate Lid Pressure 2 14 Mount for Micro Switch 1 15 Micro Switch 1 979255 16 Lid Spring...

Page 19: ...reach of this or any other express or implied warranty with respect to the Goods ii This express warranty is the only warranty applicable It excludes all other express oral or written warranties and a...

Page 20: ...ed VACMASTER and VacStrip are trademarks or registered trademarks of ARY Inc in the United States and other countries ARYInc ARY Inc P O Box 412888 Kansas City MO 64141 www VacMasterFresh com 800 821...