ENGLISH
- 58 -
PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
EnSA
Enabling Energy Saving
no
no
Function not enabled
Si
Function enabled
t.APP
Partial opening time (pedestrian access)
8.0”
0.0” - 1’00
If a Pedestrian Start command is received, the control unit opens the
SUPERIOR gate leaf only, for as reduced time (adjustable time from 0.0” to
1’00)
t .ChP
Partial closing time (pedestrian access)
9.0”
0.0” - 1’00
In the case of partial opening, the control unit uses this time for closing.
The maximum time that can be set is equal to the closing time for the
SUPERIOR gate leaf (adjustable time from 0.0” to 1’00).
NOTE
: The avoid the gate leaf not closing completely, it is recommended a
longer time be set than that used for opening
t.APP
r.AP
Gate leaf delay during opening
1.0”
0.0” - 1’00
During opening, the INFERIOR gate leaf starts to move after the SUPERIOR
gate leaf, with a delay equal to the length of time set by this menu
(adjustable time from 0.0” to 1’00).
NOTE
: If
r.AP
is set to
0
, the control unit does not check the correct
closing order of the gate leaves
r.Ch
Gate leaf delay during closing
5.0”
0.0” - 1’00
During closing, the SUPERIOR gate leaf starts to move after the INFERIOR
gate leaf, with a delay equal to the length of time set by this menu
(adjustable time from 0.0” to 1’00)
t.SEr
Lock time
2.0”
0.5” - 1’00
Before the opening phase begins, the control unit will energize the electric
lock in order to release it and enable the gate motion (adjustable time
from 0.0” to 1’00)
no
Function deactivated
SEr.S
Silent Locking Mode
Si
Si
Silent Mode (100 Hz)
WARNING: In some cases, there may be problems when unlocking.
If problems should occur, select the Standard mode
no
Standard Mode (50 Hz)
12 - PROGRAMMING THE CONTROL UNIT
The configuration menu
-PrG
consists in a list of configurable
items; the display shows the selected item.
By pressing
i
, you will pass to the next item; by pressing
h
, you
will return to the previous item.
By pressing
OK
, you can view the current value of selected item
and possibly change it.
The last menu item (
End
) allows storing the carried out changes
and going back to the control unit normal operation.
You must exit from programming mode through this menu item if
you do not want to lose your configuration.
m
WARNING: in case no operation is carried out for more
than one minute, the control unit exits from the
programming mode without saving any of your setups and
changes, which will get lost.
By holding down the
i
or
h
keys, configuration menu items will
scroll fast, until item
End
is viewed.
In this way, you can quickly reach either the top or bottom of the
list.
t.APP
EnSA
FinE
-PrG
Summary of Contents for ZORUS
Page 2: ...165 306 250 62 46...
Page 33: ...ENGLISH 65...
Page 36: ...ENGLISH 68...
Page 37: ......