background image

ENGLISH

- 7 -

EU DECLARATION OF CONFORMITY AND 
DECLARATION OF INCORPORATION OF 
PARTLY COMPLETED MACHINE  

Declaration in accordance with Directives: 2014/35/UE (LVD); 
2014/30/UE (EMC); 2006/42/CE (MD) ANNEX II, PART B

The manufacturer V2 S.p.A., headquarters in 
Corso Principi di Piemonte 65, 12035, Racconigi (CN), Italy

Under its sole responsibility hereby declares that:

the partly completed machinery model(s): 
VULCAN-230V, VULCAN-230V-S, VULCAN-120V, VULCAN-24V

Description: electromechanical actuator for gates

•  is intended to be installed on gates, to create a machine 

according to the provisions of the Directive 2006/42/EC.  
The machinery must not be put into service until the final 
machinery into which it has to be incorporated has been 
declared in conformity with the provisions of the Directive 
2006/42/EC (annex II-A).

•  is compliant with the applicable essential safety requirements 

of the following Directives: 
Machinery Directive 2006/42/EC (annex I, chapter 1)

  Low Voltage Directive 2014/35/EU
  Electromagnetic Compatibility Directive 2014/30/EU
  Directive ROHS2 2011/65/CE

The relevant technical documentation is available at the national 
authorities’ request after justifiable request to:

V2 S.p.A., Corso Principi di Piemonte 65, 
12035, Racconigi (CN), Italy

The person empowered to draw up the declaration and to provide 
the technical documentation:

Giuseppe Pezzetto

Legal representative of V2 S.p.A.
Racconigi, il 01/06/2015

 

TECHNICAL ASSISTANCE SERVICE

For any installation problem please contact our Customer Service 
at the 39-0172.812411 operating Monday to Friday
from 8:30 to 12:30 and from 14:00 to 18:00.

IMPORTANT REMARKS

V2 S.p.A. has the right to modify the product without 
previous notice; it also declines any responsibility to 
damage or injury to people or things caused by improper 
use or wrong installation.
m Please read this instruction manual very carefully 
before installing and programming your control unit.

•  This instruction manual is only for qualified technicians, who 

specialize in installations and automations.

•  The contents of this instruction manual do not concern the end 

user.

•  Every programming and/or every maintenance service should 

be done only by qualified technicians.

AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE 
WITH THE EUROPEAN REGULATIONS IN FORCE:

  EN 60204-1

 (Machinery safety. electrical equipment of 

machines, part 1: general rules) 

  EN 12445

 (Safe use of automated locking devices, test 

methods)

  EN 12453

 (Safe use of automated locking devices, 

requirements)

•  The installer must provide for a device (es. magnetotermical 

switch) ensuring the omnipolar sectioning of the equipment 
from the power supply. 
The standards require a separation of the contacts of at  
least 3 mm in each pole (EN 60335-1).

•  The plastic case has an IP55 insulation; to connect flexible or 

rigid pipes, use pipefittings having the same insulation level. 

•  Installation requires mechanical and electrical skills, therefore it 

shall be carried out by qualified personnel only, who can issue 
the Compliance Certificate concerning the whole installation 
(Machine Directive 98/37/EEC, Annex IIA).

•  The automated vehicular gates shall comply with the following 

rules: EN 12453, EN 12445, EN 12978 as well as any local rule 
in force. 

•  Also the automation upstream electric system shall comply with 

the laws and rules in force and be carried out workmanlike.

•  The door thrust force adjustment shall be measured by means 

of a proper tool and adjusted according to the max. limits, 
which EN 12453 allows.

•  We recommend to make use of an emergency button, to be 

installed by the automation (connected to the control unit 
STOP input) so that the gate may be immediately stopped in 
case of danger.

•  The appliance is not to be used by children or persons with 

reduced physical, sensory or mental capabilities, or lack of 
experience and knowledge, unless they have been given 
supervision or instruction.

•  Children being supervised do not play with the appliance.

Summary of Contents for Vulcan

Page 1: ...Value moves the world ZIS142 IL 245 EDIZ 08 05 2017 VULCAN GB IRREVERSIBLE ELECTROMECHANICAL ACTUATOR UNDERGROUND INSTALLATION FOR LEAF GATES...

Page 2: ...147 5 200 224 343 37 5...

Page 3: ...carefully before installing and programming your control unit This instruction manual is only for qualified technicians who specialize in installations and automations The contents of this instruction...

Page 4: ...00 2 5 x 550 3 x 400 3 5 x 350 2 x 800 2 5 x 550 3 x 400 3 5 x 350 2 x 800 2 5 x 550 3 x 400 3 5 x 350 Power supply V Hz 24 120 60 230 50 230 50 Idling current A 1 3 1 5 1 5 Maximum current absorption...

Page 5: ...oundation box see paragraph about Installation of the stop limit switches INSTALLATION LAYOUT 1 1 2 4 3 C 5 D A B LENGTH OF THE CABLE 10 metres from 10 to 20 metres from 20 to 30 metres Power supply 2...

Page 6: ...Install a conduit for the electrical cables and another for drainage 4 Embed the foundation box in concrete ensuring it is level and plumb mWARNING ensure that the concrete used is properly cured pri...

Page 7: ...attach the limit switch screw as shown in the figure 2 Place the gate in the maximum open position and then attach the limit switch nut as shown in the figure and tighten the screw 3 Mount the motor c...

Page 8: ...TION extensions of the cables must be made only with a 4x0 22 shielded cable with polyethylene sheath mATTENTION connect the shielding braith sheath to the common accessories Check that the ground of...

Page 9: ......

Reviews: