PARAMETER VALUE
DESCRIPTION
DEFAULT MEMO
Ch.tr
Closing after transit
This function allows having a fast closing as soon as transit through
the door is completed, therefore, a time shorter than
Ch.A U
is
generally used
no
no
Function deactivated
0.5” - 20.0’
The door closes after the setup time
PA .tr
Pause after transit
In order to let the door open for the shortest possible time, it is possible
to stop the door once the passage before the photocells is detected.
If the automatic working is enabled, the time of the pause is
Ch.tr
.
no
no
Function deactivated
Si
Function activated
LUCI
Courtesy lights
Thanks to the output COURTESY LIGHT the control unit PD11 allows the
connection of an electric appliance (e.g. courtesy light or garden lights),
controlled automatically or by means of the special transmitter key.
The PD11 central unit also has a light bulb included as a courtesy light.
t.LUC
t.LUC
The relay closes when a start or a pedestrian start control is given
and opens after the set time. It works in the same way whit a
remote control on channel 4
1 ’00
CiCL
The relay keeps closed during the whole opening/closing phase
A US
Auxiliary output with settable operation logic
t iM
TIMER: the relay closes when a remote control arrives on channel 4 and
opens after the set time
biSt
BISTABILE: the relay changes each time a remote control arrives on
channel 4
Mon
MONOSTABILE: the relay keeps closed until a signal given by the remote
control on channel 4 arrives
St .rt
Start input function
StA n
StA n
Standard functioning of the Start input according to the
menu settings
no
The Start input from a terminal board is not on.
The cycle can only be activated via radio
StoP
Stop Input
no
no
The input STOP is not available
ProS
The input STOP stops the door: pressing the command START
the door continues the motion
invE
The command STOP stops the door: at the next START the
door starts moving in the opposite direction
Foto
Photocell input
CFCh
CFCh
Input enabled even at standstill door too: the opening movement does
not start if photocell is interrupted
no
Input disabled (ignored by the control unit)
Ch
Input enabled for the closing phase only
m
Warning:
if you select this option, you must disable photocell
test.