INSTALLATION LAYOUT
1
URSUS actuator
cable 4 x 0,75 mm
2
2
Control unit
cable 3 x 1,5 mm
2
3
Flashing light with built-in antenna
power supply cable 2 x 1 mm
2
- antenna cable RG58
4
Photocells
cable 4 x 0,5 mm
2
(RX) - cable 2 x 0,5 mm
2
(TX)
5
Key switch
cable 2 x 1 mm
2
6
Transmitter
-
7
Pillar photocells
cable 4 x 0,5 mm
2
(RX) - cable 2 x 0,5 mm
2
(TX)
8
Pillar-mounted digital radio switch
-
9
In-ground central stop
OBLIGATORY
10
Side stops
OBLIGATORY
11
Electrolock