CONNECT THE OPERATOR TO THE
CONTROL UNIT
m
Before making any electrical connections,
check the switchboard instructions manual.
1.
Connect the operator to the control unit.
C
common
G1
turning 1
G2
turning 2
T
earth
2.
Connect the capacitor (C) in cable connectors Turn 1
and Turn 2.
m
Ensure the earth cable is properly connected.
3.
Connect the control unit to the power supply.
4.
Activate the power power supply switch.
m
Before carrying out any gate movement,
ensure there is no person or object in the radius
of action of the gate and the drive mechanisms.
5.
Use the control unit pushbuttons (CLOSE/OPEN) to check the
motor connections are correct (turning direction).
Se il senso di rotazione non è giusto scambiare i cavi
G1
e
G2
.
6.
If the turning direction is not correct,
interchange the cables G1 and G2.
POSITION THE END CAP AND TIGHTEN
THE GLAND
1.
Position the end cap (1) in its housing (2) and attach
using the screws (3).
2.
Tighten the gland (4) to ensure the electrical cable
input (5) is seal tight.