36 - PARAMETERS SETTING MODE
After completing the
LS
and
LP
procedures, the control unit is
ready to operate with the default parameters or with the latest
parameters set by the installation technician. It is possible to
change the settings using the keys of the control unit and relative
display.
To change the adjustments of the table below, proceed as follows:
1.
press the +/- keys to show the number of the parameter to be
modified:
01
opening speed,
02
closing speed, etc.;
2.
press ENT: the value of the parameter present is shown;
3.
select the desired value with the +/- keys then press ENT to
confirm the value selected: the value is saved by the control
unit;
4.
press ESC to end the procedure
NOTE:
if the keys are not pressed for 10 seconds during the
adjustment, the control unit exits the procedure and returns to
normal operation mode.
The table below shows the parameters and relative display code:
ID
DESCRIPTION
ADJUSTMENT
DEFAULT
01
Opening speed
20cm/s ÷ 70cm/s adjustment step 5cm/s.
60
02
Closing speed
10cm/s ÷ 40cm/s, adjustment step 5cm/s.
20
03
Pause time
0 - 60
seconds, adjustment step 1 second
0
04
Opening anti-crushing
1 – 9
(1 minimum, 9 maximum)
9
05
Closing anti-crushing
1 – 9
(1 minimum, 9 maximum)
7
06
Partial opening percentage
30 - 90
percentage of opening in relation to total
50
07
Approach speed
3cm/s ÷ 10cm/s adjustment step 1cm/s.
5
08
Accelerations
5 - 30
adjustment step 1
24
09
Decelerations
5 - 20
adjustment step 1
16
10
Approach
10cm - 40cm adjustment step 1cm modification of both values (opening equal
to 1/2 of closing)
20
11
Opening limit
0% - 50% adjustment step 1%. Movement limit in relation to travel of the leaf
0
12
Door closed hold force
0 - 9
adjustment step 1, 0 disabled, 9 maximum
0
13
Type of electric lock
0
Not used
1
Normal
2
Inverted
3
Bistable
4
Safety bistable with motor door lock only is KEY active
1
14
Door lock logics with electric lock
or motor
0
Lock deactivated
1
Lock active in One Radar
2
Lock active in Two Radar
3
Lock active in One Radar and Two Radar
If no electric lock is selected the door is locked by the motor
1
15
Auxiliary 1 input configuration
(defining NO / NC type of
parameter 26)
0
Emergency open
1
Interlock Master
2
Interlock Slave
3
Opening pharmacy mode
4
Repeat command Start 2
5
Semiautomatic
6
Stop motion
7
Partial opening command
1
16
Auxiliary 2 input configuration
(defining NO / NC type of
parameter 27)
0
Emergency open
1
Interlock Master
2
Interlock Slave
3
Opening pharmacy mode
4
Repeat command Start 2
5
Semiautomatic
6
Stop motion
7
Partial opening command
0
17
Auxiliary output configuration
(defining NO / NC type of
parameter 29)
0
Not used
1
Interlock
2
Status door Open
3
Status door Close
4
Fault
5
Bell
0