ENGLISH
- 57 -
PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
Ch.tr
Closing after transit
During the automatic operation, the pause count down starts from the set
up value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be
immediately stored as pause time.
This function allows having a fast closing after the transit through the
barrier, for which usually a lesser time for
Ch.AU
(automatic closing) is
used.
no
no
Function deactivated
0.5” - 20.0’
The barrier recloses after the time set
PA.tr
Pause after the transit
no
Si
In order to render minimum the time in which the barrier remains open,
it is possible to make the barrier close as soon as the passage in front of
photocells has ended. If the automatic operation is enabled, the
Ch.tr
value is loaded/programmed as time of pause
no
Function deactivated
LUCi
Courtesy lights
This menu allows setting up the operation of the courtesy lights
automatically during the barrier’s opening cycle.
t.LUC
t .LUC
Timed functioning (from 0 to 20’)
1 ’00
no
Function disabled
CiCL
Turned on for the entire duration of the cycle
AUS
Auxiliary channel
This menu allows setting the operating of the relay of the lighting of the
courtesy lights by means of a remote control stored on the channel 4 of
the receiver MR
Mon
t iM
Timed functioning (from 0 a 20’)
biSt
Bistable functioning
Mon
Monostable functioning
SPiA
Setting low voltage light output
FLSh
FLSh
Flashing function (fixed frequency)
no
Function disabled
W.L.
Spy lamp function: it indicates in real time the state of the barrier, the type
of flash indicates the four possible conditions:
- BARRIER CLOSED the light is off
- BARRIER IN PAUSE the light is on fixed
PLEASE NOTE
: the light remains off if the ENERGY SAVING function is
enabled and automatic closure is deactivated
- BARRIER IN OPENING the light blinks slowly (2Hz)
- BARRIER IN CLOSING the light blinks fast (4Hz)
LP.PA
Flashing lamp in pause
no
no
Function disabled
Si
The flashing lamp works also during the pause time (barrier opened with
active automatic closing).
Summary of Contents for 36A022
Page 2: ...1153 mm 320 mm 287 mm 218 mm 897 mm 1168 mm 374 mm 239 mm 319 mm 897 mm...
Page 7: ...ITALIANO 5 NIUBA4 NIUBA6...
Page 11: ...ITALIANO 9 FIG 3 FIG 4...
Page 13: ...ITALIANO 11 A D E C F F G E A B D C O N M...
Page 31: ...ITALIANO 29...
Page 34: ...ITALIANO 32...
Page 39: ...ENGLISH 37 NIUBA4 NIUBA6...
Page 43: ...ENGLISH 41 FIG 3 FIG 4...
Page 45: ...ENGLISH 43 A D E C F F G E A B D C O N M...
Page 63: ...ENGLISH 61...
Page 66: ...ENGLISH 64...
Page 71: ...FRAN AIS 69 NIUBA4 NIUBA6...
Page 75: ...FRAN AIS 73 FIG 3 FIG 4...
Page 77: ...FRAN AIS 75 A D E C F F G E A B D C O N M...