ELECTROMAGNETIC VACUUM GRIPPER
The control unit is equipped with an output for feeding
an electromagnetic vacuum gripper. Through a dedicated menu it
is possible to regulate the output voltage up to a maximum value
of 24Vdc. The power supply to the electromagnetic vacuum
gripper is interrupted at the beginning of every opening (with
adjustable anticipation from the menu) and restored at the end of
the closing (with adjustable delay from the menu).
Connect the power supply to the electromagnetic vacuum
gripper between terminals
G4 (+)
and
G5 (-)
PLEASE NOTE: The locking electromagnet is connected to
the accessory power supply. Hence, it is essential to
deactivate the energy saving function to use it.
LOCK-OUT (prewired)
The input BLOCCO is connected to a microswitch set in action
from the blocking lock of the inspection access flap.
In case of opening of the inspection access flap, the control unit
gets blocked: in this condition the boom movement commands
coming from the activation inputs or the remote controls are not
accepted.
For viewing of the programming menu and for setting the
boom’s actions, only the functions operated with the push-
buttons MENU, UP, DOWN are allowed.
ENCODER (prewired)
The control unit controls the barrier’s set in motion
through the encoder.
The motors speed of operation in continuum flow can be
conditioned from the voltage variations and atmospheric
condition.
Moreover, the encoders also allow recognizing if the barrier jams
in an abnormal position because of an obstacle.
For the encoders operation it is indispensable that the barrier’s
closing position is noticeable through a mechanical stop.
With every ignition of the control panel, the first working cycle
causes the alignment of the encoder on the point of arrest in
closing.
EXTERNAL AERIAL
We suggest to use the external aerial (model: ANSGP433) in
order to guarantee the maximal range.
Connect the antenna hot pole to terminal
L1
of the control unit
and the braiding to terminal
L2
.
PLUG IN RECEIVER
control unit is suitable for plugging in a Personal Pass
MRx receiver having a high-sensitivity super-heterodyne
architecture.
m
WARNING: it is necessary to turn off the control unit
power before doing the operations mentioned here below.
1.
Insert the module receiver paying maximum attention to the
direction of the coupling.
2.
Power up the control panel again
MRx module receiver is provided with 4 channels and each of
them is suitable for a command of
control unit:
CHANNEL 1
쩚쩛
START
CHANNEL 2
쩚쩛
PEDESTRIAN START
CHANNEL 3
쩚쩛
STOP
CHANNEL 4
쩚쩛
COURTESY LIGHT
m
WARNING: Before programming 4 channels and
function logics read carefully the instructions of MRx.
INTERFACE
The ADI (Additional Devices Interface) interface of the control
unit
allows the connection to V2 optional modules.
Refer to V2 catalogue or to the technical sheets to see which
optional modules with ADI interface are available for this control
unit.
m
WARNING: Please read the instructions of each single
module to install the optional modules.
Summary of Contents for 36A004
Page 2: ......
Page 9: ...ITALIANO 7 Fig 3...
Page 11: ...ITALIANO 9...
Page 16: ...ITALIANO 14...
Page 34: ...ITALIANO 32 INSTALLAZIONE DELL ACCESSORIO 163604...
Page 41: ...ENGLISH 39 Fig 3...
Page 43: ...ENGLISH 41...
Page 48: ...ENGLISH 46...
Page 66: ...ENGLISH 64 INSTALLATION OF THE ACCESSORY 163604...
Page 73: ...FRAN AIS 71 Fig 3...
Page 75: ...FRAN AIS 73...
Page 80: ...FRAN AIS 78...
Page 98: ...FRAN AIS 96 INSTALLATION DE L ACCESSOIRE 163604...
Page 105: ...ESPA OL 103 Fig 3...
Page 107: ...ESPA OL 105...
Page 112: ...ESPA OL 110...
Page 130: ...ESPA OL 128 INSTALACI N DEL ACCESORIO 163604...
Page 131: ......
Page 132: ......