position.
Clean Air Filters
The message informs that the item "Elapsed Time" in the "Fixture Information" menu is at 0 value. Clean air
filters and reset this counter.
Messages concerning the lamp and lamp driver:
Lamp Starting
The message informs you that the lamp status is on but the lamp does not light.
Overtemp
The message informs you that the fixture had been overheated and the lamp was shut down due to excessive
temperature.
Start Failure
The message informs you that the lamp failed to start within 30 secs.
Run Failure
The message informs you that the lamp was shut down while running.
Too Warm
The message informs you that the lamp is too warm.
General Failure
The message informs you that the internal failure was sensed as temp. sensor failure.
28V Failure
The message informs you that the lamp was shut down due to undervoltage.
28V Low
The message informs you that the DC voltage falls below undervoltage limit.
10. Technical Specifications
Electrical:
Power supply:.........................electronic auto-ranging
Input voltage range:............... supply 100-240V, 50/60Hz
.
.
Live Fuse:...............................T 6.3 A
Neutral Fuse:..........................T 6.3 A
Power consumption:...............400 VA
Light source:
LIFI ENT 31-02, CRI=94
Optical System:
Metal reflector
.
.
.
zoom range: 10°-40°
Colour wheel:
7 replaceable 'SLOT&LOCK' dichroic filters (including UV filter)
CMY + CTO mixing module
Smooth CMY colour mixing system
.
.
.
Colour temperature correction filter lowers colour temperature from 6000K to 3200 K
30 colour macros
Summary of Contents for Robin 300 plasma spot