EN-04
Setting up
• Avoid positioning the appliance in direct sunlight or near cookers,
radiators and similar sources of heat.
• Standard EN 378 specifies that the room in
which you install your appliance must have
a volume of 1 m
3
per 8 g of R 600a refriger
-
ant used in the appliance, so as to avoid the
formation of inflammable gas/air mixtures in
the room where the appliance is located in the
event of a leak in the refrigerant circuit. The
quantity of refrigerant used in your appliance
is indicated on the identification plate on the
inside of the appliance.
•
Do not cover ventilation openings
or grilles.
Electrical connection
Only operate the appliance with
alternating current (AC)
.
The permissible voltage and frequency are indicated on the iden
-
tification plate. The position of the identification plate is shown in
the section entitled
Description of the appliance
.
The socket must be properly earthed and protected by a fuse.
The tripping current of the fuse must be between 10 A and 16 A.
The socket must not be situated behind the appli
-
ance and must be easily accessible.
Do not connect the appliance using an exten
-
sion cable or extension socket.
Do not use stand-alone inverters (conversion
of direct current to alternating/three-phase
current) or energy-saving plugs. Risk of dam
-
age to the electronic control system!
Climate rating
Depending on the climate rating, the ap
-
pliance is designed to operate in restricted
ambient temperatures. The climate rating
of your appliance is printed on the iden
-
tification plate.
Keep to the specified ambient tempera
-
tures in order to guarantee that the appli
-
ance works properly.
Climate rating
Room temperature
SN
+10°C to +32°C
N
+16°C to +32°C
ST
+16°C to +38°C
T
+16°C to +43°C
SN-ST
+10°C to +38°C
SN-T
+10°C to +43°C
Door opening mechanism (TouchOpen)
The TouchOpen function is disabled
when the appliance is delivered.
The TouchOpen function must be
enabled after installation in the recess by
pressing the
button.
Opening the door
Push the door slightly inwards on the top
left-hand side and release again.
The door is opened approx. 7 cm by the
push rod.
The door can then be fully opened.
Note
The door will close again automati
-
cally after approx. 3 seconds if it
has not been fully opened.
Note on door opening
cycles
If the door is closed, it can only
be opened again using the
TouchOpen function after 3
seconds.
Important notes
Do not operate the appliance near magnetic fields or
place magnetic objects near the appliance.
The door may otherwise open when you do not want
it to.
Do not block the door or hold on to it while it is
opening.
If the door is blocked or held open during opening, the internal
safety coupling will be activated.
Loud, repeated cracking noises will be heard.
Do not push the push rod in or hold on to it during
closing.
If the push rod is blocked during
closing, it will no longer be able to
reach its initial position.
In the initial position, the push rod is
flush with the front of the appliance.
Setting the push rod back in its initial position
Disconnect the appliance from the mains, wait for approx.
5 seconds and plug it back in again.
The push rod returns to its initial position.