background image

Installation instructions

Toptronic
GK45TE
Glass ceramic hob

1039710-R02

05/03/2019

1039710-R02

2

Installation accessories provided

Normal mounting frame:

Designation

Remarks

Art. no.

Mounting angle, right/left

For GK45TESC, GK45TEBSC/.1C, GK45TEGC only

H62484

Large mounting angle, back

For GK45TEASC only

H62221

Large mounting angle, front

For GK45TEASC only

H62408

Mounting angle, right/left

For GK45TEASC only

H62409

Wood screws for mounting angle

Diverse

Flush installation:

Designation

Art. no.

Cementing-in instructions

J004133

Sealing strip set

H63283

Spacer set

H60330

Oversize mounting frame:

Designation

Art. no.

Mounting angle, right/left

H62484

Adjusting brace set for special installation cases

H61548

Wood screws for mounting angle

Diverse

Accessories

For all installation variants:

Designation

Art. No.

Thermal shielding plate set for GK45TEBS…, GK45TEXS…, GK45TES…, GK45TEG…

H62622

Thermal shielding plate set for GK45TEAS…

H62617

Instant adhesive for installing the steel angles
Permabond F246 incl. activator, 50 ml tube. From Silitech AG, 3008 Bern.

B11502

Normal mounting frame:

Designation

Art. No.

Adjusting brace set for special installation

H61548

Flush installation:

Designation

Art. no.

Steel angle set, installation dimension 60

H63772

Steel angle set, installation dimension 70

H63773

Steel angle set, installation dimension 80

H63774

Cement set
Complete with cleaning agent, primer type 1105, cartridge with black silicone adhesive, with nozzle. Suitable for all ab-
sorbent worktop materials (wood and natural stones such as marble or granite).

86.3928.85

Special primer type 107
Suitable for non-absorbent worktop materials (not suitable for polyethylene, polypropylene or Teflon).

45.2771.76

Summary of Contents for Toptronic GK45TEASC

Page 1: ...1104 GK45TEGC GK45TEGZ 31105 GK45TESC GK45TESCO GK45TESZ GK45TESZO GK45TESU GK45TESUO 31106 GK45TEXSC GK45TEXSCO GK45TEXSZ GK45TEXSZO 31107 GK45TEASC GK45TEASCO GK45TEASZ GK45TEASZO GK45TEASU General notes If installing into a combustible material the guidelines and standards for low voltage installations and fire protection must be strictly observed Identification plate The identification plate i...

Page 2: ...rse Accessories For all installation variants Designation Art No Thermal shielding plate set for GK45TEBS GK45TEXS GK45TES GK45TEG H62622 Thermal shielding plate set for GK45TEAS H62617 Instant adhesive for installing the steel angles Permabond F246 incl activator 50 ml tube From Silitech AG 3008 Bern B11502 Normal mounting frame Designation Art No Adjusting brace set for special installation H615...

Page 3: ... PE PE PE yellow green black brown L2 grey yellow green L3 grey L2 black L1 brown L1 N blue L1 brown L2 black yellow green N blue L1 brown yellow green Error message U400 Faulty connection A pole conductor has been connected to the connection terminal for neutral conductors Quickly disconnect the appliance from the mains General information about installation The distance from the appliance cut ou...

Page 4: ...ucer B H Corner radius Ra Ri GK45TEBSC GK45TEGC GK45TESC GK45TESCO GK45TEXSC GK45TEXSCO GK45TEASC GK45TEASCO 20 mm 66 5 mm 46 5 mm 10 8 mm A Worktop depth in combination with directly built under oven does not apply to small appliances B Required clearance for service replacement H Dimension from the top of the work surface to the underside of the hob ventilation opening Ri Corner radii of applian...

Page 5: ... touch the hot areas of the tray located underneath the cooking zones Overlying installation The layout of the hob to be fitted may differ from the hob illustrated 4 9 0 1 5 0 5 0 A 680 1 600 550 Ra 571 5 0 1 Y Y Ri H 4 9 0 1 560 1 5 0 5 0 A 600 550 Ra 5 0 1 Ri H 691 Y Y 4 9 0 1 5 0 5 0 750 1 600 550 A Ra 5 0 1 761 Y Y Ri 20 B Y Y Drawer cabinet Cable length 1 7 m Cable length 1 7 m Cable length 1...

Page 6: ...0 550 275 H X X H 20 Y Y B Drawer cabinet Side panel C D Ra R0 5 8 5 0 1 8 5 0 0 5 8 5 8 5 1 0 1 0 Detail Z Steel angle mounted with adhesive or screws GK45TEBSZ GK45TEGZ GK45TESZ GK45TESZO GK45TEASZ GK45TEASZO GK45TEXSZ GK45TEXSZO The required clearance must be observed Type A Depends on producer B C D H Corner radius Ra Ri GK45TEBSZ GK45TEGZ GK45TESZ GK45TESZO 20 mm 90 mm 560 490 50 mm 5 1 5 mm ...

Page 7: ...3 0 A Ri Ra GK45TESU GK45TESUO 750 775 4 9 0 5 3 0 600 550 B A 790 Y Y 5 4 5 Ri Ra X X 20 550 B H Drawer cabinet H 20 Drawer cabinet Y Y GK45TEASU Cable length 1 7 m Cable length 1 7 m L K Centering mark rear middle of cut out Centering marks front K M Centering mark middle of cut out Set of fixing brackets for special installation cases The required clearance must be observed Type A Depends on pr...

Page 8: ...t areas of the tray located underneath the cooking zones The appliances with oversize frames can also be used as a replacement for solid plate hobs and for installation in complete chrome nickel steel covers In the latter case the solid plate hob part is cut out of the chrome nickel steel cover and replaced by an appliance depth of the work surface 30 mm In contrast to normal installation without ...