Installation instructions
Induction hob
GK11TIFKZ | GK11TIFKZS | CTI6T96FKTFHD
1032691-10
22/06/2022
1032691-10
2
Electrical connection
Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards
for low-voltage installations and the specifications of the local electricity supply companies.
Refer to the identification plate for information on the required mains voltage and current type.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Check old installa-
tions.
▸
If the hobs are used at an altitude of over 2,000 metres, a reduced performance must be expected.
The appliance is equipped with a connection cable which must be connected to an on-site junction box.
Installation pipe
Distribution box
Clamp
brown
blue
yellow/green
grey
blue
yellow/green
brown
L3
L1
N
N
L1
PE/
PE/
black
L2
400 V 3N~ / 16 A
230 V~ / 48 A
blue
yellow/green
brown
L1
N
PE/
black
L2
400 V 2N~ / 16 A
3106200.../3106203.../3106260.../3106266...
3113400001–3113400003/3113400005
3106261.../3106265.../3106267...
3113400004
E35/U0 error message
Incorrect connection:
Pole conductor connected to connection terminal for neutral conductor.
Quickly disconnect the appliance from the mains!