background image

Installation instructions

Built-in variants of gas hob
Multi-sliders GAS411/421/641/951

1014422-R09

27/07/2017

1014422-R09

5

Connect to the electrical mains connection before inserting the appliance, if necessary.

Combination installation

Flush combination installation is described in document 1014381. The intermediate support kit H63789 is required for this.

Electrical connection

Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards
for low-voltage installations and the specifications of the local electricity supply companies.

A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Check old installa-
tions.

Refer to the identification plate for information on the required mains voltage, current type and fuse protection.

The connection cable has either a plug or three stranded wires.
Plug-in appliances must be connected to an easily accessible power socket.
Appliances with stranded wires must be connected by a qualified electrician via a junction box according to local regulations.

Installation pipe

Distribution box

Clamp

The mains plug must not be cut off.

Error message U400

Incorrect connection:
Pole conductor connected to connection terminal for neutral conductor or voltage too high.

Quickly disconnect the appliance from the mains!

Ventilation

In order to guarantee minimum ventilation, a space of ≥20 mm height is ne-
cessary beneath the appliance.

≥15

B

A

A

The rear panel of the base unit must be open around the work surface
cut-out to guarantee continuous air circulation via the ventilation slits.
The air must be drawn in from outside the cabinet and be able to circu-
late freely from inside the cabinet to the hob.

B

Alternatively, a concealed fresh air supply can ensure air circulation in-
side the cabinet.
So that enough cold air can be drawn in, there must be a continuous
supply of fresh air circulating till outside the cabinet.
The air must be drawn in from outside the cabinet and be able to circu-
late freely from inside the cabinet to the hob.

Summary of Contents for GAS411GSBZ

Page 1: ...entilation requirements If installing into a combustible material the guidelines and standards for low voltage installations and fire protection must be strictly observed Validity These installation i...

Page 2: ...installation Designation Article no Steel angle set hob size 40 H63771 Steel angle set hob size 60 H63772 Steel angle set hob size 90 H63775 Designation Article no Instant adhesive for installation of...

Page 3: ...adii of cut out S Minimum distance between the top of the work surfaces and any drawer T Minimum distance between the cut out in the back and any drawer 1 Front and rear struts may be reinforced on th...

Page 4: ...ut S Minimum distance between the top of the work surfaces and any drawer T Minimum distance between the cut out in the back and any drawer 1 Front and rear struts may be reinforced on the underside T...

Page 5: ...accessible Check old installa tions Refer to the identification plate for information on the required mains voltage current type and fuse protection The connection cable has either a plug or three st...

Page 6: ...0 mm 750 450 When a range hood is installed above the gas hob the minimum distance given for the particular range hood must be observed Furthermore the minimum distances illustrated must be strictly c...

Page 7: ...e with ISO 228 1 If the gas installation on site already has a corresponding counterpart the gas appliance can be directly connected to it It is imperative to use the sealing ring for the front end se...

Page 8: ...e left of the button Use the first active slider to the left of the button to change the values The left half of the slider functions as the minus button and the right half functions as the plus butto...

Page 9: ...a wok burner Remove central injector nozzles using 7 mm socket wrench Remove horizontal injector nozzles in the wok burner using an open end wrench Screw in the new injector nozzles according to the t...

Reviews: