background image

Installation instructions

Induction hob with integrated range hood
GKD46TIMASZO - Fusion

1039697-R02

06/09/2018

1039697-R02

3

The appliance is equipped with a connection cable which must be connected to an on-site junction box.

Installation pipe

Distribution box

Clamp

brown + black

blue

yellow/green

black

blue

yellow/green

brown

L2

L1

N

N

L1

PE/

PE/

400 V 2N~ / 16 A

230 V~ / 32 A

Error message U400

Faulty connection:
A pole conductor has been connected to the connection terminal for neutral conductors.

Quickly disconnect the appliance from the mains!

Ventilation

There must be a sufficient supply of fresh air in order to ensure good ventilation.

Dimensions

All plastering, plasterboarding, wall papering or painting work is to be carried out prior to installing the appliance.
Ensure that the material is sufficiently stable.

Plan a removable base plate or service flap for fan motor (and recirculation box in the case of the recirculation
mode).

For the recirculation mode, ensure sufficient ventilation so that moisture can escape. Plan in suitable material/wood.

225

778

73

398

347

761

501

126

206

222

ø146

89

176

108

X

X

52

60

129.5

333

188

256

60

(145)

330

165

37

(165)

(203.5)

58.5

256 

56

53

8

129.5

1.

3.

2.

1.

The exhaust ducting can be to the left or right.

2.

The fan motor can be turned, this changes the installation type.

3.

Depending on space requirements, the position of the fan motor can be adjusted by shortening the flat channel.

Summary of Contents for Fusion 31094

Page 1: ...end piece H Fan motor General notes If installing into a combustible material the guidelines and standards for low voltage installations and fire protection must be strictly observed If other firing...

Page 2: ...te silicone FA880 310 ml B11556 White silicone FA880 310 ml 1031313 Stone grey silicone FA880 310 ml 1031314 Marble smoothing agent AA320 1000 ml B11557 Fugenboy silicone finishing tool B75158 Electri...

Page 3: ...der to ensure good ventilation Dimensions All plastering plasterboarding wall papering or painting work is to be carried out prior to installing the appliance Ensure that the material is sufficiently...

Page 4: ...m B H 5 0 1 Ri 761 Y Y 4 9 0 1 5 0 A 5 0 Ra 750 1 825 900 Type A Depends on producer B H Corner radius Ra Ri GKD46TIMASZO 20 70 mm 212 mm 202 mm 5 1 5 mm A Worktop depth B Required clearance for servi...

Page 5: ...to the underside of the hob Ri Corner radii of appliance Ra Outer corner radii of cut out W The intermediate base must be removable from below Installation 1 Create an accurate mounting cut out The m...

Page 6: ...on with depth of 700 546 600 699 430 300 450 250 230 202 20 70 97 333 33 105 650 100 1000 132 646 700 530 400 550 250 230 202 20 70 97 333 33 105 650 100 1000 132 F Island installation with depth of 9...

Page 7: ...on opening for service replacement purposes as shown in the diagrams observe exhaust air duct to left or right 330 700 600 330 330 180 220 330 330 330 232 232 180 220 330 330 700 330 330 600 232 232 P...

Page 8: ...Installation instructions Induction hob with integrated range hood GKD46TIMASZO Fusion 1039697 R02 06 09 2018 1039697 R02 8 1 2 1 2 3 1 2 1 2 2 1 6 5 7 4 1 3 2 8...

Page 9: ...ating instructions for using the appliance for the first time Mount grease filters left and right in filter cassette Insert filter cassette Check the range hood and exhaust ducting for tightness and n...

Page 10: ...09 2018 1039697 R02 10 Metal accessories J 1012161 1046643 1046644 1046627 1046628 1046629 1046635 1046636 1030590 1046639 1046636 1012161 J 1046629 1046635 1046629 1046635 1046627 1046628 1046627 10...

Page 11: ...annel or pipe The diameter of the exhaust duct pipe must not be less than 150 The exhaust ducting should be as short and straight as possible Only use connection elbows with large radii The exhaust du...

Page 12: ...r recirculation operation Recirculation mode with recirculation box Connect the channel connector K to the recirculation box J Hold the button depressed for 1 second An acoustic signal is emitted and...