background image

Installation instructions

Induction hob with integrated range hood
GKD46TIMASZO - Fusion

1039697-R02

06/09/2018

1039697-R02

2

Recirculation mode

The ventilation outlet must not be covered during operation.

Dedicated accessories that need to be fitted to operate the appliance in the recirculation mode: 1012161 recirculation
box with activated charcoal filters!

Install the recirculation box with activated charcoal filter in the base or adjacent cabinet.

If the recirculation box is not equipped with activated charcoal filters, these have to be ordered and installed before using the appli-
ance for the first time.

Installation accessories supplied

Designation

Art. no.

Aluminium tape

H42067

Flush installation:

Designation

Art. no.

Cementing-in instructions

J004133

Sealing strip set

H63283

Spacer set

H60330

Accessories

Flush installation:

Designation

Art. no.

Steel angle set, installation dimension 80

H63774

Instant adhesive for installation of the steel angle (50 ml)

B11657

Straight mixing nozzle

B11656

TREMCLEAN isopropyl alcohol (1000 ml)

1056609

Black silicone FA880 (310 ml)

B11555

Anthracite silicone FA880 (310 ml)

B11556

White silicone FA880 (310 ml)

1031313

Stone grey silicone FA880 (310 ml)

1031314

Marble smoothing agent AA320 (1000 ml)

B11557

Fugenboy (silicone finishing tool)

B75158

Electrical connection

Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards
for low-voltage installations and the specifications of the local electricity supply companies.
Refer to the identification plate for information on the required mains voltage, current type and fuse protection.

A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Check old installa-
tions.

If the hobs are used at an altitude of over 2,000 meters above sea level, a reduced performance must be expected.

Summary of Contents for Fusion 31094

Page 1: ...end piece H Fan motor General notes If installing into a combustible material the guidelines and standards for low voltage installations and fire protection must be strictly observed If other firing...

Page 2: ...te silicone FA880 310 ml B11556 White silicone FA880 310 ml 1031313 Stone grey silicone FA880 310 ml 1031314 Marble smoothing agent AA320 1000 ml B11557 Fugenboy silicone finishing tool B75158 Electri...

Page 3: ...der to ensure good ventilation Dimensions All plastering plasterboarding wall papering or painting work is to be carried out prior to installing the appliance Ensure that the material is sufficiently...

Page 4: ...m B H 5 0 1 Ri 761 Y Y 4 9 0 1 5 0 A 5 0 Ra 750 1 825 900 Type A Depends on producer B H Corner radius Ra Ri GKD46TIMASZO 20 70 mm 212 mm 202 mm 5 1 5 mm A Worktop depth B Required clearance for servi...

Page 5: ...to the underside of the hob Ri Corner radii of appliance Ra Outer corner radii of cut out W The intermediate base must be removable from below Installation 1 Create an accurate mounting cut out The m...

Page 6: ...on with depth of 700 546 600 699 430 300 450 250 230 202 20 70 97 333 33 105 650 100 1000 132 646 700 530 400 550 250 230 202 20 70 97 333 33 105 650 100 1000 132 F Island installation with depth of 9...

Page 7: ...on opening for service replacement purposes as shown in the diagrams observe exhaust air duct to left or right 330 700 600 330 330 180 220 330 330 330 232 232 180 220 330 330 700 330 330 600 232 232 P...

Page 8: ...Installation instructions Induction hob with integrated range hood GKD46TIMASZO Fusion 1039697 R02 06 09 2018 1039697 R02 8 1 2 1 2 3 1 2 1 2 2 1 6 5 7 4 1 3 2 8...

Page 9: ...ating instructions for using the appliance for the first time Mount grease filters left and right in filter cassette Insert filter cassette Check the range hood and exhaust ducting for tightness and n...

Page 10: ...09 2018 1039697 R02 10 Metal accessories J 1012161 1046643 1046644 1046627 1046628 1046629 1046635 1046636 1030590 1046639 1046636 1012161 J 1046629 1046635 1046629 1046635 1046627 1046628 1046627 10...

Page 11: ...annel or pipe The diameter of the exhaust duct pipe must not be less than 150 The exhaust ducting should be as short and straight as possible Only use connection elbows with large radii The exhaust du...

Page 12: ...r recirculation operation Recirculation mode with recirculation box Connect the channel connector K to the recirculation box J Hold the button depressed for 1 second An acoustic signal is emitted and...