background image

Installation instructions

Range hood
Operating modes: Extraction/recirculation
DWPQ9, DWPQ12

1039460-R01

13/12/2017

1039460-R01

3

Installing

Fix angle bracket 

C

 to motor housing with 2 screws 

S3.

Drill holes for wall angle bracket  

W

.

S3

C

Fix wall angle bracket 

W

 to the wall with appropriate fasteners

(bolt anchors 

BA

 or rawlplugs 

DL

) and 2 screws  

S5

Fit hood to wall mounting bracket 

W

 and screw lightly with 2

nuts 

G

.

Align hood horizontally using adjusting screws 

S6

.

Mark 2 holes (ø8 mm) for screws 

S7

, take down the hood, drill

holes and insert rawlplugs.

Fit hood and tighten nuts 

G

.

Fix with 2 screws 

S7

 (ø5 × 40 mm) and fit dummy covers 

D

.

Drill 2 holes (ø8 mm) for screws 

S8

 – aligned with appliance –

in the wall under the ceiling and insert plugs.

400

750

650

11

90 90

125 125

W

J

S5

W

Fix metal support 

J

 with 2 screws 

S8

 (ø5 × 40 mm).

Fix exhaust air hose to exhaust air connector. If non-return
valve flap is used, test after installation to see if functioning
properly.

Make electrical connection (see section on 'Electrical connec-
tions').

For recirculation mode:

 Connect diverter piece 

K

 to exhaust

air hose and screw to metal support 

J

 with 4 screws 

S9

(ø3.5 × 6 mm).

For extraction mode:

 Connect exhaust air hose to exhaust air

pipe wall-side.

Fit lagging sheets 

L1, L2

. Align lagging sheet 

L1

 vertically and

screw to metal support 

J

 with 2 screws 

S10

 (ø3.5 × 6 mm).

For recirculation mode:

 Adjust air outlet grille in side of upper

casing to face upwards.

For extraction mode:

 Adjust air outlet grille of upper casing to

face downwards.

Insert grease filters.

Carry out function test.

J

S6

G

S8

S9

S10

K

R

L1

L2

S7

D