background image

Electric interface for comfort ventilation appliances from Zehnder Comfosystems

 

 

 

Cable colour

12 V

GND

CH

Tch

1

2

3

4

 

1

blue

 

2

yellow

 

3

red

 

4

black/white

 

The electric interface at the side of the comfort ventilation appliance must be declared safety extra-low voltage (SELV) in
accordance with IEC 60335-1 3.4.2.

Dimensions

 

The positioning of the Zehnder insert box Z in the ceiling must be planned and coordinated in relation to the hob.
Max. positional deviation: ±1 cm (in all directions)

280

280

750

485

1200

100

ø 160

B

*

Z

* Grid spacing: 10 mm

Telescopic casing
(available in various heights)
Height A: see planning documents for kitchen appliances

Distance above hob
Minimum height B:
For electric hob:
For gas hob:

min. 600 mm
min. 750 mm

Installation

Note

Planning features for non-destructive de-installation and maintenance of the appliance.
– Do not route telescopic casing in suspended ceilings.
– Avoid silicon joints between the telescopic casing and the appliance.
– All plastering, plasterboarding, wall papering or painting work is to be carried out prior to installing the appliance.

This appliance is to be fastened directly under the Zehnder insert box, which must be precisely attached to the ceiling beforehand.

The supply air connection from the Zehnder insert box must be freely accessible. Always follow the manufacturer’s installation

instructions and safety precautions.

Installation instructions

 

J016.113-2

Range hood DI-SMC12

 

12.12.12

Island hood

 

 

Operating mode: extracted air with comfort ventilation system

 

 

2