Installation
1. Affix paper template C to the ceiling – aligning it with the supply air
connection from the Zehnder insert box. Make drill holes for suitable
screw mounting as per the manufacturer’s instructions (see package
leaflet).
2. Fasten the exhaust air hose D (min. ø 160 mm) to the supply air connec-
tion.
3. Adjust carrier supports T1, T2 to adequate length (grid spacing: 10 mm)
and fasten securely with 8 screws S1 (ø 4 × 8 mm).
4. Fix carrier supports to the ceiling with screws S2. Follow the manufactur-
er's instructions for screw mounting (see package leaflet).
5. Fit upper lagging sheets V1, V2 with cage nuts M. Screw both halves
together with the spring F and screw S3 (M4 × 7 mm). Slide from bottom
onto carrier supports.
6. Screw in 4 screws S4 (ø 4 × 8 mm) at the bottom to carrier support T2.
Hang the hood H in the key holes.
7. Remove the grease filters.
8. Tighten screws S4 and additionally secure the hood with 4 screws S5
(ø 4 × 8 mm) from below and with 2 screws S6 (ø 4 × 8 mm) from above.
9. Establish plug connection G.
10. Remove cover E.
Establish electrical connection (see 'Electrical connections').
Refer for this to the installation instructions for the comfort ventilation
system.
Put cover E back.
11. Fasten exhaust air hose D to the exhaust air connection. Ensure hose is
free from kinks and is stretched.
12. Fix upper lagging sheets V1, V2 with 2 screws S7 (ø 3 × 9 mm).
13. Fit lower lagging sheet V4 with cage nuts M and from rear put onto carrier
support T2. Attach lower lagging sheet V3 from the front and screw both
halves together with spring F and screw S3 (M4 × 7 mm).
14. Install lower cover strips U2. Cut upper cover strips U1 to adequate length
and fit them.
15. Reinstall the grease filters.
U1
U2
S6
T2
D
H
E
G
V2
V3
V4
C
S2
V1
T1
6./8.
15.
U2
U1
T1
T2
S1
3.
T2
H
S4
S5
5./14.
13.
V1, V3
V2, V4
M
F
S3
S7
V2
T1
V1
F
U1
S3
Installation instructions
J016.113-2
Range hood DI-SMC12
12.12.12
Island hood
Operating mode: extracted air with comfort ventilation system
3