background image

Installationsanleitung

CombiSteamer with fixed water connection
Bauform 60-450

1063723-03

11/02/2021

1063723-03

4

Water connections

≥50

50–700

100

±30

2

7

3

5

6

1

4

1

 Hose clamp

2

 Reinforced inlet hose 2 m, G ¾"

3

 Drain hose 3 m

Internal diameter of connection 22 mm

On-site installation:

4

 Drain trap

5

 Plinth panel

6

 Hose fed through plinth

7

 Cold water connection with stopcock

Water outlet

Length of drain hose: 3 m

The drain hose must not be lengthened or shortened.
The drop from the bottom of the appliance to the drain trap must be at least 50 mm.
The drain hose must be laid flat without any kinks.

Connecting the drain

1.

Mount the hose clamp 

1

.

2.

Remove the blind cap and non-return flap valve 

 on the drain

trap.

3.

Clean the drain trap.

4.

Fit the drain hose in the hose clamp.

5.

Lay the drain hose without any kinks.

6.

Connect the drain hose to the drain trap.

2

1