background image

Installationsanleitung

CombiSteamer with fixed water connection
Bauform 60-450

1063723-03

11/02/2021

1063723-03

5

Connecting the drain for an installed dishwasher

1.

Mount the hose clamp 

1

.

2.

Remove the hose to the dishwasher

 

on the drain trap.

3.

Remove the adapter, blind cap and non-return flap valve 

2

.

4.

Clean the drain trap.

5.

Connect the double connection 

3

 to the drain trap.

Note:

 The double connection is 

NOT

 included in the scope

of delivery.

6.

Connect the hose for the dishwasher

 

to

 

the double connection.

7.

Fit the drain hose in the hose clamp.

8.

Lay the drain hose without any kinks.

9.

Connect the drain hose to the double connection.

3

2

1

Cold water connection

Operating pressure: 0.1–1.0 MPa (1–10 bar)

May only be used if the water hardness >3° French hardness (>1.7° German hardness).

Length of reinforced hose: 2 m

Local water authority regulations must be observed.
Existing hoses that are defective must be replaced.
The reinforced hose must not be extended.
The stopcock must be accessible at all times.

Connecting the inlet

1.

Clean the sealing surface on the stopcock.

2.

Connect the reinforced hose to the stopcock and tighten using
water pump pliers.

3.

Check the seal.

Connecting the inlet for the installed dishwasher

1.

Remove the hose to the dishwasher

 

on the stopcock.

2.

Clean the sealing surface on the stopcock.

3.

Connect T-section 

1

.

Note:

 The T-section is 

NOT

 included in the scope of deliv-

ery.

4.

Connect the reinforced hose to the T-section and tighten with
pipe pliers.

5.

Connect the hose to the dishwasher on the T-section and
tighten with pipe pliers.

6.

Check the seal.

1