11 Care and maintenance
11.5
Replacing the door seal
▸ Remove the damaged door seal.
▸ Clean the groove
1
with a slightly damp
cloth.
▸ Press the ends of the new door seal
2
into the groove in the centre of the frame
at the bottom.
3
4
2
1
The ends must touch each other
but not overlap.
▸ Ensure that only the thinner part
3
of the
seal is pressed into the groove; the
thicker part
4
must not be in the groove.
▸ Starting from the bottom, press the seal
evenly into the groove.
11.6
Replacing the door seal on pyrolysis appliances
▸ Remove the damaged door seal.
▸ Clean the groove
3
with a slightly damp cloth.
▸ Press the new door seal
1
into the groove, with the
seam joint
2
not at centre bottom of the frame
2 3
1
▸ Ensure that only the thinner part
4
of the seal is
pressed into the groove; the thicker part
5
must
not be in the groove.
4
5