3 Operating the appliance

Reset the saturation indicator after cleaning.

▸ Switch the appliance and the illumination off.
▸ Hold the 

 button depressed for 5 seconds.

The 

 or 

 symbols in the display go out.

Only activate the saturation indicator for the activated charcoal filter if the appli-
ance is being used in the recirculation mode. For more details, see: Using for the
first time (see page 10).

3.8 

OptiLink

With this function, the user no longer needs to control the range hood manually. OptiLink
monitors the power levels set for the cooking zones and automatically sets the optimum
power level for the range hood.
The following settings are available for selection: 

-

OFF

OptiLink is turned off

Silent mode

Low noise level operation

Standard mode

Normal mode

Intensive mode

High power for extracting cooking fumes and

smells

Establishing a connection from the range hood to the hob

The range hood can only be connected to hobs that have the OptiLink function.

▸ For activating the «connecting mode» on the hob: see the operating instructions for

the hob.

▸ For activating the «connecting mode» on the range hood:
▸ Switch the appliance and the illumination off.
▸ With the appliance switched off, hold the 

 button depressed for 5 seconds.

The 

 display symbol flashes when the «connecting mode» is active.

If a connection could be established to the hob, 

 illuminates for 10 seconds and

then the range hood is ready for both OptiLink and manual operation.

– If no connection could be established, the 

 display symbol stops flashing. In this

case, another attempt at establishing a connection can be made.

▸ If a connection could be established, this must be confirmed on the hob. See the op-

erating instructions for the hob for this.

The buttons and operating elements on the range hood are deactivated during the
connection process.

A range hood may be connected to as many as three hobs. And a single hob may
be simultaneously connected to several range hoods. Establishing a connection
requires appliances are equipped with OptiLink.

13

Summary of Contents for AiroClearWall V6000

Page 1: ...Operating instructions AiroClearWall V6000 AiroClearIsland V6000 Range hood...

Page 2: ...ard of the appliance at the time these operating instructions went to press The right to make technical modifications for the purpose of the further development of the appliances is reserved Validity...

Page 3: ...ce 10 3 1 Using for the first time 10 3 2 Switching the appliance on off 11 3 3 Selecting power level 11 3 4 Illumination 11 3 5 After running time 12 3 6 Wipe protection 12 3 7 Saturation indicators...

Page 4: ...e This appliance can be used by children aged 8 and above and by persons with reduced physical sensory or mental capabilities or lack of experi ence and or knowledge provided they are supervised or ha...

Page 5: ...ome and similar settings such as in staff kit chens in shops offices and other commercial establish ments in agricultural estab lishments by guests in hotels motels and other accommod ation establishm...

Page 6: ...s cus tomer service department or similarly qualified persons Repairs if carried out incorrectly may cause serious injury damage to the appliance and fittings as well as affect the functioning of the...

Page 7: ...g oil keeping it below the temperature at which it can catch fire Change the cooking oil regularly dirty oil catches fire more easily than clean oil Caution Risk to life Packaging material e g plastic...

Page 8: ...with activated charcoal filter A fan extracts cooking fumes and smells from above the cooking surface The air is passed through the metal grease filter and activated charcoal filter grease particles a...

Page 9: ...fter running time Display symbols Wipe protection After running time Power level 1 Power level 2 Power level 3 Intensive level flashing Saturation indicator for grease filter Saturation indicator for...

Page 10: ...nger displayed The appliance is now configured for the extraction mode and the saturation indic ator for the activated charcoal filter is deactivated Setting up the appliance for use in the recirculat...

Page 11: ...vel and the corresponding symbol or illuminates in the display Intensive level The intensive power level runs for 5 minutes It is used for short bursts of intensive ex traction of cooking fumes and sm...

Page 12: ...ore start ing to cook Leave the appliance running for a few minutes after cooking so as to extract all the cooking smells 3 6 Wipe protection The wipe protection function temporarily deactivates the k...

Page 13: ...be connected to hobs that have the OptiLink function For activating the connecting mode on the hob see the operating instructions for the hob For activating the connecting mode on the range hood Swit...

Page 14: ...as a power level is assigned to a cooking zone The range hood maintains power level 1 for the dur ation of the reaction time according to the mode selected before the power level is adjusted to the ho...

Page 15: ...n off the OptiLink function on the hob Hold the button on the range hood depressed for 15 seconds During this time the display symbol for after running time should start to flash and then go out again...

Page 16: ...densate water can build up on the inside around the metal grease filters Clean using a clean damp cloth and a mild detergent or a soft brush as needed then dry well using kitchen towel 4 2 Metal greas...

Page 17: ...damaged Cleaning Clean the metal grease filters in the dishwasher Select the intensive dishwasher programme If no dishwasher is available Soak the grease filters in hot water and mild detergent Clean...

Page 18: ...rail Cleaning and regenerating Heat the activated charcoal filter unit in the oven Select top bottom heat or hot air at 200 C and regenerate on the wire shelf for 60 minutes Allow to cool down After...

Page 19: ...upply Change the fuse Reset the automatic circuit breaker Illumination is not working LED light bulb is defective Contact Customer Services Malfunction Possible cause Solution Appliance is not ex trac...

Page 20: ...ficiency FDEhood 36 3 36 3 36 3 Fluid Dynamic Efficiency Class FDEC A A A Lighting Efficiency LEhood lux W 28 0 33 0 28 0 Lighting Efficiency Class LEC A A A Grease Filtering Efficiency GFEhood 89 5 8...

Page 21: ...in an environmentally friendly way 8 2 Safety Render the appliance unusable to prevent accidents caused by improper use e g through children playing Disconnect the appliance from the mains With a fix...

Page 22: ...I Identification plate 20 Illumination 11 Initial set up 6 M Model designation 2 O Operating and display elements 9 Operation 10 OptiLink 13 P Product fiche 21 Q Queries 23 R Recirculation mode 8 Remo...

Page 23: ...hem on the identification plate of your appliance My appliance information SN __________________________ Appliance ______________________________ Please have this appliance information to hand when co...

Page 24: ...g time Display symbols Wipe protection After running time Power level 1 Power level 2 Power level 3 Intensive level flashing Saturation indicator for grease filter Saturation indicator for activated c...

Reviews: