TYPE OF
FAULT
CODE
NAME
DESCRIPTION
RECOMMEND SOLUTION
Inner
Warnning
I04
EnvirTempAdChan-
Warning
Some temperature
sensors abnormal
• The warnings are not mat-
ter influence.
• Power off, then restart (Ref.
Chapter8).
• If those faults occurs
continuously and frequent-
ly, please ask help for local
distributors.
I05
CoolingTempAd-
ChanWarning
I06
Temp3AdChanWarn-
ing
I07
ExtFlashComWarning
Flash abnormal
• Power off, then restart (Ref.
Chapter8).
• If this those faults continu-
ously and frequently, please
ask help for local distribu-
tors.
I08
EepromComWarning
Eeprom abnormal
I09
SlaveComWarning
Communication
between slaver CPU
and master CPU
abnormal
I10
HmiComWarning
HMI abnormal
I11
FreqCalcCon-
flictWarning
Frequency value ab-
normal
I12
UnsetModel
Running model is not
initial
• Contact with local distrib-
utor.
Outside
Warnning
J01
MeterComWarning Meter/CT abnormal
• Check the smart meter
model, connection or con-
nectors are correct, any
loose.
• if abnormal, repair or
change.
• Power off, then restart (Ref.
Chapter8).
• If those faults occurs
continuously and frequent-
ly, please ask help for local
distributors.
J02
MeterCon-
nectWarning
Wires connecting
type of meter wrong
• Check Meter/CT connec-
tion, installed place, and
installed dire tion.
• if abnormal, re-installation.
• Power off, then restart (Ref.
Chapter8).
• If this those faults continu-
ously and frequently, please
ask help for local distribu-
tors.
J03
SohWarning
Battery SOH low
Contact with Battery manu-
facturer.