3D Alpha+
User’s
Manual
52
6.2.2.4
Remote Server
–
Step 4
In this page, connection methods to a reporting server is displayed. By default, all V-Count
devices are set to connect to
cloud.v-count.com
address.
Also, the Serial IDs of the devices are set at factory installation and not allowed to be changed
afterwards.
Figure 56 Remote Server Settings
The connection types are TCP, and MQTT.
cloud.v-count.com
supports only MQTT
connection for Slave Device. By default, MQTT is set at factory settings for connection to
cloud.v-count.com.
MQTT connection is used only for web interface connection from
cloud.v-
count.com.
Slave device does not send any Wi
–
Fi or BLE data to cloud server.
“Counting Period”
is used to adjust the interval that device stores and sends the counting
results to Master device. It is set in terms of
seconds
. Minimum value is 1 minute and
maximum value is 60 minutes. The
counting is reset at every period.
TCP:
This connection uses TCP/IP sockets to
connect to Master Device. A specially
defined message format is sent to
“Server
IP”
address from
“Sender Port”
.
“Listener
Port”
is used if QoS(ACK) is set to “1” for
handshaking with the Master device
server. It is recommended to be used
only by the V-Count technicians.
Figure 57 TCP Connection Settings